Settlement and load sharing behavior of piled raft foundation: a review

DK Malviya, A Ansari, M Samanta - Innovative Infrastructure Solutions, 2023 - Springer
Piled rafts are increasingly being used to support different heavy infrastructure facilities. The
total resistance of piled raft is cumulative of shallow component, ie, raft and deep …

Serviceability-based finite-element approach on analyzing combined pile–raft foundation

A Bhaduri, D Choudhury - International Journal of Geomechanics, 2020 - ascelibrary.org
The present study proposes a finite-element approach to focus on the load sharing and
deformation aspects of combined pile–raft foundation (CPRF) in a serviceability-based …

CFG pile composite foundation: its engineering applications and research advances

BU Uge, YC Guo - Journal of Engineering, 2020 - Wiley Online Library
Problematic soils exist almost everywhere on the globe. State‐of‐the‐art solutions to make
civil engineering infrastructures built on them are still highly sought. The CFG (cement‐fly …

Large scale model testing to investigate the influence of granular cushion layer on the performance of disconnected piled raft system

P Halder, B Manna - Acta Geotechnica, 2021 - Springer
This paper presents the results of 1 g model tests performed on instrumented model
foundations, ie, unpiled raft, single piled raft, single disconnected piled raft (DPR) and 3× 3 …

Displacement-based finite element approach on analysing flexible combined pile–raft foundation in layered soil

A Bhaduri, D Choudhury - Canadian Geotechnical Journal, 2023 - cdnsciencepub.com
The present study proposes a new finite element methodology to analyse the behaviour of
flexible combined pile–raft foundation (CPRF) situated in layered soil, in a displacement …

Non-linear soil–structure interaction in disconnected piled raft foundations

F Tradigo, F Pisanò, C Di Prisco, A Mussi - Computers and Geotechnics, 2015 - Elsevier
Disconnected piled raft foundations are characterised by no structural connection between
the upper raft and the underlying piles, mostly playing the role of settlement-reducers. The …

3D dynamic finite element analyses and 1 g shaking table tests on seismic performance of connected and nonconnected piled raft foundations

AS Azizkandi, MH Baziar, AF Yeznabad - KSCE Journal of Civil …, 2018 - Springer
Connected and disconnected piled raft foundations have been evaluated under lateral cyclic
loading in this study. Connected Piled Raft (CPR) and nonconnected piled (NPR) …

A novel cushioned piled raft foundation to protect buildings subjected to normal fault rupture

H Rasouli, B Fatahi - Computers and Geotechnics, 2019 - Elsevier
Recent earthquake events have shown that besides the earthquake forces, interaction
between the fault rupture and structure could cause a lot of damage to the surface and …

Seismic response of nuclear power station with disconnected pile-raft foundation using dynamic centrifuge tests

Y Yang, H Fan, YP Cheng, W Gong, G Dai… - Journal of Cleaner …, 2022 - Elsevier
The typical foundation type for a nuclear power station is the raft foundation in rock areas.
With the power demand, it is possible that a nuclear power station located in soft soil areas …

Comparative analysis of various interaction effects for piled rafts in sands using centrifuge tests

D Park, J Lee - Journal of Geotechnical and Geoenvironmental …, 2015 - ascelibrary.org
In the current study, the load responses and interaction effects of piled rafts embedded in
sands were investigated. A series of centrifuge load tests were conducted using different …