Development and validation of a 1.5 T MR‐Linac full accelerator head and cryostat model for Monte Carlo dose simulations

M Friedel, M Nachbar, D Mönnich, O Dohm… - Medical …, 2019 - Wiley Online Library
Purpose To develop, implement, and validate a full 1.5 T/7 MV magnetic resonance (MR)‐
Linac accelerator head and cryostat model in EGSnrc for high precision dose calculations …

Monte-Carlo simulation of the Siemens Artiste linear accelerator flat 6 MV and flattening-filter-free 7 MV beam line

A Sadrollahi, F Nuesken, N Licht, C Rübe, Y Dzierma - PLoS One, 2019 - journals.plos.org
The aim of our work is to provide the up-to-now missing information on the Siemens Artiste
FFF 7 MV beam line using a Monte-Carlo model fit to the realistic dosimetric measurements …

Determination of initial electron parameters by means of Monte Carlo simulations for the Siemens Artiste Linac 6MV photon beam

T Tuğrul, O Eroğul - Reports of Practical Oncology and …, 2019 - journals.viamedica.pl
Aim In this study, we investigated initial electron parameters of Siemens Artiste Linac with
6MV photon beam using the Monte Carlo method. Background It is essential to define all the …

Monte Carlo Simulation for the Radixact™ Tomotherapy Linac Using EGSnrc

DS Makrani, HA Nedaei, G Geraily… - Journal of Medical …, 2024 - journals.lww.com
Purpose: When exact information regarding the treatment head and initial electron beam is
available, the Monte Carlo (MC) approach can properly simulate any linear accelerator …

Numerical model simulating the therapeutic electron beam of a clinical linear accelerator

IA Miloichikova, BM Gavrikov, AA Krasnykh… - Biomedical …, 2020 - Springer
We present here the results of developing a numerical model of therapeutic electron beams
from a clinical accelerator, which is required to solve the task of defining the transverse …

Evaluation of Lung Dose in Esophageal Cancer Radiotherapy Using Monte Carlo Simulation

T Pourfallah, M Seyed Abousaeedi… - … of Medical Sciences, 2020 - jmums.mazums.ac.ir
Background and purpose: Radiation therapy make an important contribution in the control
and treatment of cancers. Lungs are the main organs at risk in esophageal cancer …

[HTML][HTML] CALCULATION OF SPINAL CORD RECEIVED DOSE IN ESOPHAGEAL CANCER RADIOTHERAPY: A COMPARISON BETWEEN MONTE CARLO …

T Pourfallah, M Nematpour… - Studies in Medical …, 2024 - umj.umsu.ac.ir
Background & Aim: Spinal cord is one of the organs at risk in esophageal cancer radiation
therapy. The difference between the dose distribution due to the Treatment Planning System …

[PDF][PDF] Формирование дозных полей индивидуальной конфигурации клинических пучков электронов с помощью полимерных изделий, изготовленных …

ИА Милойчикова - 2018 - earchive.tpu.ru
Для современного общества проблема онкологических заболеваний остается
приоритетной. По данным Всемирной организации здравоохранения количество …

[PDF][PDF] محاسبه دز دریافتی نخاع در پرتودرمانی سرطان مری؛ مقایسه شبیه‌سازی مونت‌کارلو و سیستم طراحی درمان

پورفلاح, طیب, نعمت پور, محمد, سیفی ماکرانی… - مجله مطالعات علوم …, 2024‎ - umj.umsu.ac.ir
Pourfallah T, Nematpour M, Seifi Makrani D, Mihandoust E, Davodian S. CALCULATION OF
SPINAL CORD RECEIVED DOSE IN CANCER RADIOTHERAPY: A COMPARISON …

Siemens artiste lineer hızlandırıcı cihazının Monte Carlo Yöntemi kullanılarak modellenmesi ve enerjiye etki eden parametrelerin değerlendirilmesi

T Tuğrul - 2020 - 193.140.108.196
Radyoterapinin amacı, tümöre yüksek dozda radyasyon verirken, tümörün etrafında bulunan
sağlıklı dokuları en iyi şekilde korumaktır. Bu amaca ulaşmak için, elde edilen doz dağılımı …