Improving power quality by a four-wire shunt active power filter: A case study

M Popescu, A Bitoleanu, M Linca, CV Suru - Energies, 2021 - mdpi.com
This paper presents the use of a three-phase four-wire shunt active power filter to improve
the power quality in the Department of Industrial Electronics of a large enterprise from …

Assessment and comparison of different neutral current compensation techniques in three-phase four-wire distribution system

A Negi, S Surendhar, SR Kumar… - 2012 3rd IEEE …, 2012 - ieeexplore.ieee.org
There were many harmonic and neutral current mitigation methods evolved earlier to
address the power quality problem but each solution has its own limitation. A brief …

Analysis and application of zigzag transformer in distribution system for mitigation of triplen harmonics

SK Shaikh, AM Mulla, SU Bagwan… - 2020 5th International …, 2020 - ieeexplore.ieee.org
The three-phase four wires low voltage supply system to residential, commercial and
production areas in the distribution system is implemented. The different nature of loads …

Analyzing the Impact of Electric Vehicles Charging Stations on Power Quality in Power Distribution Systems

A Hamadi, MS Alam, SA Arefifar - 2021 - sae.org
Integration of electric vehicles (EV) in power distribution systems reduces emissions that
contribute to climate changes and improves public health by reducing ecological damage …

[PDF][PDF] Комплексне покращення якості електроенергії та забезпечення електробезпеки в локальних системах електропостачання при застосуванні гібридних …

АФ Жаркін, ВО Новський… - Технічна …, 2018 - irbis-nbuv.gov.ua
Розглянуто основні аспекти використання розроблених гібридних
фільтрокомпенсуючих перетворювачів (ГФКП), які виконані на основі регульованого …

[PDF][PDF] Improving power quality by a four-wire shunt active power filter: A case study. Energies 2021, 14, 1951

M Popescu, A Bitoleanu, M Linca, CV Suru - 2021 - academia.edu
This paper presents the use of a three-phase four-wire shunt active power filter to improve
the power quality in the Department of Industrial Electronics of a large enterprise from …

Investigation for harmonic mitigation in the line and neutral currents of three-phase four-wire system feeding two-pulse rectifiers with balanced and unbalanced load …

AN Arvindan, C Sanal - 2014 IEEE 2nd International …, 2014 - ieeexplore.ieee.org
In the commercial sector single-phase, non-linear loads are predominant and their numbers
are on the increase. These low-power loads include conventional single-phase power …

Frequency domain model for zero‐sequence electromagnetic harmonic filter performance analysis

JC Oliveira, LCO Oliveira, FN Belchior… - … on Electrical Energy …, 2015 - Wiley Online Library
Using frequency domain approach, this paper focuses on a zero‐sequence harmonic filter
model. The model is based on electromagnetic arrangement created through a three …

The interaction of submarine cables and the power quality of an oil rig's electrical system

RM Vidaurre, MZ Fortes - Electrical Engineering, 2020 - Springer
Electrical power systems are becoming more susceptible to disturbances in the power grid
such as harmonic distortions. The reason for this is the improvement of power in electronics …

[PDF][PDF] Complex improvement of power quality and ensure electrical safety in local power supply systems when using hybrid filter compensating converters

AF Zharkin, VO Novskyi… - Tekhnichna …, 2018 - academia.edu
DOI: https://doi.org/10.15407/techned2018.01.069 COMPLEX IMPROVEMENT OF POWER
QUALITY AND ENSURE ELECTRICAL SAFETY IN LOCAL POWE Page 1 2018 N1 st10 DOI …