Zero-sequence circulating current reduction method for parallel HEPWM inverters between AC bus and DC bus

TP Chen - IEEE Transactions on industrial electronics, 2011 - ieeexplore.ieee.org
In this paper, a real-time circulating current reduction method for parallel harmonic-
elimination pulsewidth modulation (HEPWM) inverters is proposed. HEPWM techniques are …

A source-current-detected shunt active power filter control scheme based on vector resonant controller

H Yi, F Zhuo, Y Zhang, Y Li, W Zhan… - IEEE Transactions on …, 2013 - ieeexplore.ieee.org
A shunt active power filter (APF) with current detection at the source side is considered as a
closed-loop system from the view of the whole power distribution system, which is expected …

Low-order dominant harmonic estimation using adaptive wavelet neural network

SK Jain, SN Singh - IEEE Transactions on Industrial Electronics, 2013 - ieeexplore.ieee.org
In recent years, harmonic pollution has worried the power engineers considerably due to the
increased penetration of power-electronics-based devices in the utility grid. Monitoring of …

A modified ABC algorithm approach for power system harmonic estimation problems

Y Kabalci, S Kockanat, E Kabalci - Electric power systems research, 2018 - Elsevier
Electrical harmonic is an important issue on power quality of electrical systems. Therefore,
estimation of power harmonics are essential to design filters to be utilized in electrical power …

[HTML][HTML] Improved predictive direct power control of shunt active power filter using GWO and ALO–Simulation and experimental study

Y Bekakra, L Zellouma, O Malik - Ain Shams Engineering Journal, 2021 - Elsevier
In order to reduce the maximum overshoot and undershoot of the DC-link voltage variation,
and minimize power ripples with low current distortion in accord with IEEE Std. 519–2014 …

Robust deadbeat control scheme for a hybrid APF with resetting filter and ADALINE-based harmonic estimation algorithm

Y Han, L Xu, MM Khan, C Chen, G Yao… - IEEE Transactions on …, 2010 - ieeexplore.ieee.org
A novel hybrid active power filter (HAPF) topology is proposed, which shows advantages of
the conventional HAPF and the LCL filter in terms of reduced dc-link voltage, lower switching …

Harmonic linearization and investigation of three-phase parallel-structured signal decomposition algorithms in grid-connected applications

S Golestan, JM Guerrero, JC Vasquez… - … on Power Electronics, 2020 - ieeexplore.ieee.org
In practice, because of different factors, the supply voltage (especially in the distribution
level) almost always has some degrees of imbalance and harmonic pollution. With …

Control scheme for grid‐tied distributed generation inverter under unbalanced and distorted utility conditions with power quality ancillary services

R Chilipi, N Al Sayari, K Al Hosani… - IET Renewable Power …, 2016 - Wiley Online Library
This study proposes a control scheme with a new fundamental sequence components
extractor for grid interfaced distributed generation inverter under polluted grid conditions …

Frequency adaptive least-squares-Kalman technique for real-time voltage envelope and flicker estimation

I Sadinezhad, VG Agelidis - IEEE Transactions on Industrial …, 2011 - ieeexplore.ieee.org
This paper presents real-time implementation of a new frequency adaptive least-squares-
Kalman (LSK) technique to monitor voltage flicker and fluctuations in power system. The …

Analysis and design of a digital phase-locked loop for single-phase grid-connected power conversion systems

Q Zhang, XD Sun, YR Zhong… - IEEE Transactions on …, 2010 - ieeexplore.ieee.org
A new digital phase-locked-loop (DPLL) method is proposed for single-phase grid-
connected power conversion systems in this paper. The analysis of a phase detector using …