Impedance measurements and modeling of a transition-edge-sensor calorimeter

MA Lindeman, S Bandler, RP Brekosky… - Review of Scientific …, 2004 - pubs.aip.org
We describe a method for measuring the complex impedance of transition-edge-sensor
(TES) calorimeters. Using this technique, we measured the impedance of a Mo/Au …

Optimized transition-edge x-ray microcalorimeter with 2.4 eV energy resolution at 5.9 keV

JN Ullom, JA Beall, WB Doriese, WD Duncan… - Applied Physics …, 2005 - pubs.aip.org
We present measurements from a series of transition-edge x-ray microcalorimeters
designed for optimal energy resolution. We used the geometry of the sensors to control their …

On the nature of the superconducting-to-normal transition in transition edge sensors

GW Fraser - Nuclear Instruments and Methods in Physics Research …, 2004 - Elsevier
A transition edge sensor (TES) is an X-ray microcalorimeter based on a thin film
superconductor voltage-biased within its resistive transition. This superconductor is usually …

Fabrication of Mo/Au transition-edge sensors for X-ray spectrometry

N Tralshawala, RP Brekosky, MJ Li… - IEEE transactions on …, 2001 - ieeexplore.ieee.org
We present fabrication details of our Mo/Au X-ray microcalorimeters, which are being
developed as one of the candidate high resolution spectrometers for the Constellation-X …

Performance of X-ray microcalorimeters with an energy resolution below 4.5 eV and 100 μs response time

WMB Tiest, HFC Hoevers, WA Mels… - AIP Conference …, 2002 - pubs.aip.org
The performance of X-ray microcalorimeters with a Ti/Au Transition Edge Sensor (TES) and
a Cu absorber has been investigated. With these microcalorimeters we achieve energy …

Performance of Mo/Au TES microcalorimeters

MA Lindeman, RP Brekosky… - AIP conference …, 2002 - pubs.aip.org
We are developing X-ray calorimeters to meet the specifications of the Constellation-X
mission. Each calorimeter consists of a transition-edge-sensor (TES) thermometer, which is …

Low-temperature detectors

G Angloher - Nuclear Instruments and Methods in Physics Research …, 2003 - Elsevier
Low-temperature detectors offer single particle detection with high-energy resolution and
low-energy threshold, what is of interest for applications both in fundamental physics and …

RF single electron transistor readout amplifiers for superconducting astronomical detectors of X-ray to sub-mm wavelengths

TR Stevenson, A Aassime, P Delsing… - IEEE transactions on …, 2001 - ieeexplore.ieee.org
We have made Radio-Frequency Single-Electron Transistors (RF-SETs) with large input
gates, and tested performance and modes of operation with the goal of using such devices …

Development of arrays of transition edge sensors for application in X-ray astronomy

MP Bruijn, WMB Tiest, HFC Hoevers, E Krouwer… - Nuclear instruments and …, 2003 - Elsevier
The development of an array of voltage biased superconducting transition edge
microcalorimeters is described. This work is directed to an application in future X-ray …

Transition edge sensors for imaging spectrometers

HFC Hoevers - Low Temperature Detectors, 2002 - ui.adsabs.harvard.edu
This paper describes single pixel microcalorimeters with a superconductor-to-normal phase
transition thermometer, as developed for high resolution X-ray spectroscopy, and discusses …