The leakage current components as a diagnostic tool to estimate contamination level on high voltage insulators

AA Salem, R Abd-Rahman, SA Al-Gailani… - IEEE …, 2020 - ieeexplore.ieee.org
The current paper presents an alternative and innovative technique to predict the severity of
pollution of high voltage insulator using a higher harmonics component with up to the 7 th …

Risk assessment of polluted glass insulator using leakage current index under different operating conditions

AA Salem, R Abd-Rahman, SA Al-Gailani… - Ieee …, 2020 - ieeexplore.ieee.org
In this article, an innovative approach to assess the risk of uniform/non-uniform pollution and
wet high voltage glass insulator is proposed. The assessment is based on a new index …

Experimental investigation on composite insulators AC flashover performance with fan-shaped non-uniform pollution under electro-thermal stress

EM Savadkoohi, M Mirzaie, SM Seyyedbarzegar… - International Journal of …, 2020 - Elsevier
Pollution deposition along with ultraviolet (UV) radiation and electro-thermal stress cause
the composite insulators to face with critical conditions. The type of pollution which settles on …

Leakage current characteristics in estimating insulator reliability: experimental investigation and analysis

AA Salem, KY Lau, W Rahiman, Z Abdul-Malek… - Scientific Reports, 2022 - nature.com
The monitoring of leakage current (LC) and voltage characteristics in transmission line
insulators is regarded as a good technique for anticipating the physical state of in-service …

Improved flashover mathematical model of polluted insulators: A dynamic analysis of the electric arc parameters

MF Palangar, M Mirzaie, A Mahmoudi - Electric Power Systems Research, 2020 - Elsevier
This paper presents an improved dynamic mathematical model of critical parameters for
ceramic insulators based on an extended equivalent electric circuit model of a polluted …

Designing an automatic detector device to diagnose insulator state on overhead distribution lines

MF Palangar, S Mohseni, M Mirzaie… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
An automatic detector device (ADD) has been designed and built for monitoring insulators
state in overhead distribution lines. The prototyped device is suitable for measurement and …

Estimation of contamination level of overhead insulators based on surface leakage current employing detrended fluctuation analysis

S Deb, S Das, AK Pradhan, A Banik… - IEEE Transactions …, 2019 - ieeexplore.ieee.org
This article proposes an advanced technique for condition assessment of outdoor insulators
based on its surface leakage current through employing detrended fluctuation analysis …

A novel leakage current index for the field monitoring of overhead insulators under harmonic voltage

R Ghosh, B Chatterjee… - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
Leakage current measurement is the most reliable and effective method for condition
monitoring of overhead insulators deployed in the field. However, a major challenge in the …

Identification of composite insulator criticality based on a new leakage current diagnostic index

MF Palangar, U Amin, H Bakhshayesh… - IEEE Transactions …, 2021 - ieeexplore.ieee.org
In this article, a new method is proposed to identify the health condition of composite
insulators through investigating the leakage current (LC) along with the electric potential …

Polymeric insulator conditions estimation by using leakage current characteristics based on simulation and experimental investigation

AA Salem, KY Lau, Z Abdul-Malek, N Mohammed… - Polymers, 2022 - mdpi.com
The current work contributes an estimate of the time-frequency characteristics of a leakage
current in assessing the health condition of a polluted polymeric insulator. A 33 kV polymer …