A DSP-based implementation of the pq theory in active power filtering under nonideal voltage conditions

M Popescu, A Bitoleanu, V Suru - IEEE Transactions on …, 2012 - ieeexplore.ieee.org
This paper presents a three-phase three-wire shunt active power filtering system based on
two level voltage source inverter which is intended to compensate both current harmonic …

Performance Enhancement of Shunt Active Power Filter Using a Kalman Filter-Based Control Strategy

R Panigrahi, B Subudhi - IEEE Transactions on Power …, 2016 - ieeexplore.ieee.org
This paper proposes a Kalman filter (KF)-based H∞ control scheme for a three-phase shunt
active power filter (SAPF) system. For the current control loop, a H∞ controller is designed …

Control of multi-functional grid-connected PV systems with load compensation under distorted and unbalanced grid voltages

MA Mantilla, JF Petit, G Ordoñez - Electric Power Systems Research, 2021 - Elsevier
This paper proposes a new algorithm in the natural abc coordinates used to control grid-
connected photovoltaic (PV) systems with load compensation functionalities under distorted …

Model predictive‐based shunt active power filter with a new reference current estimation strategy

R Panigrahi, B Subudhi, PC Panda - IET Power Electronics, 2015 - Wiley Online Library
This study presents a new reference current estimation method using proposed robust
extended complex Kalman filter (RECKF) together with model predictive current (MPC) …

Current reference control for shunt active power filters under unbalanced and distorted supply voltage conditions

X Nie, J Liu - IEEE Access, 2019 - ieeexplore.ieee.org
This paper proposes a current reference control method for shunt active power filter under
unbalanced and distorted supply voltage conditions. The method uses the Kalman filter and …

A robust LQG servo control strategy of shunt-active power filter for power quality enhancement

R Panigrahi, B Subudhi… - IEEE Transactions on …, 2015 - ieeexplore.ieee.org
This paper proposes a linear quadratic Gaussian (LQG) servo controller for the current
control of shunt-active power filter (SAPF) operating under balanced and unbalanced supply …

An optimization-based algorithm for shunt active filter under distorted supply voltages

KR Uyyuru, MK Mishra, A Ghosh - IEEE Transactions on Power …, 2009 - ieeexplore.ieee.org
In this paper, an optimization-based control algorithm for the compensation of steady-state
load under distorted supply voltages is presented. For balanced and sinusoidal supply …

[HTML][HTML] Shunt Active Power Filters in Three-Phase, Three-Wire Systems: A Topical Review

M Popescu, A Bitoleanu, CV Suru, M Linca… - Energies, 2024 - mdpi.com
The increasingly extensive use of non-linear loads, mostly including static power converters,
in large industry, commercial, and domestic applications, as well as the spread of renewable …

A DSP-based implementation of an instantaneous current control for a three-phase shunt hybrid power filter

S Rahmani, A Hamadi, K Al-Haddad… - … and Computers in …, 2013 - Elsevier
This paper presents the design and implementation of an instantaneous current control
technique for a three-phase shunt hybrid power filter (SHPF) to compensate harmonics …

Future work on harmonics-some expert opinions Part I-wind and solar power

M Bollen, J Meyer, H Amaris, AM Blanco… - … on Harmonics and …, 2014 - ieeexplore.ieee.org
A workshop on power system harmonics was organized in Stockholm in January 2014. On
the agenda was among others a discussion on what are the main issues on harmonics at …