Electrochemical Methods for the Analysis of Trace Tin Concentrations

M Grabarczyk, E Wlazlowska, M Fialek - Materials, 2023 - mdpi.com
Tin determination allows for the monitoring of pollution and assessment of the impact of
human activities on the environment. The determination of tin in the environment is crucial …

Fluorescence “turn-on” chemosensor for the selective detection of zinc ion based on Schiff-base derivative

M Hosseini, Z Vaezi, MR Ganjali, F Faridbod… - … Acta Part A: Molecular …, 2010 - Elsevier
N, N′-phenylenebis (salicylideaminato)(L) has been used to detect trace amounts of zinc
ion in acetonitrile–water solution by fluorescence spectroscopy. The fluorescent probe …

AIEE active ionic liquid based on triphenyl amine functionalized Schiff base for the selective and sensitive detection of Sn2+ ion

YB Barot, V Anand, R Mishra - Journal of Molecular Liquids, 2023 - Elsevier
A triphenylamine and imidazolium based fluorescent ionic liquid (IL)[TPA-SB][Br] was
synthesized and its structure was elucidated using 1 H, 13 C NMR, FT-IR, UV–visible …

A turn-on fluorescent sensor for Zn2+ based on new Schiff's base derivative in aqueous media

M Hosseini, A Ghafarloo, MR Ganjali, F Faridbod… - Sensors and Actuators B …, 2014 - Elsevier
In order to detect trace amounts of Zn 2+ ion in aqueous buffered solution through
fluorescence spectroscopy, Tris (3-(2-hydroxyacetophenone) propyl) amine (L) has been …

A highly selective fluorescent sensor for zinc ion based on quinoline platform with potential applications for cell imaging studies

AB Pradhan, SK Mandal, S Banerjee, A Mukherjee… - Polyhedron, 2015 - Elsevier
An 8-aminoquinoline based fluorescent Zn 2+ sensor, 2-methoxy-6-((quinolin-8-ylimino)
methyl) phenol (HL), was synthesized. It has been found to display quick responses through …

Turn-on fluorescent chemosensor for selective detection of Zn2+ in an aqueous solution: Experimental and theoretical studies

YW Choi, GR You, JJ Lee, C Kim - Inorganic Chemistry Communications, 2016 - Elsevier
A new simple receptor 1 based on the combination of julolidine and 2-(aminomethyl)
benzenamine groups was prepared. It exhibited a 'turn-on fluorescence type'mode with high …

A high-performance, disposable screen-printed carbon electrode modified with multi-walled carbon nanotubes/graphene for ultratrace level electrochemical sensors

P Pasakon, JP Mensing, D Phokaratkul… - Journal of Applied …, 2019 - Springer
In this work, a screen-printed carbon paste electrode (SPCE) combined with multi-walled
carbon nanotubes (MCNT) and graphene (GP) in different mixing ratios was fabricated …

Determination of zinc (II) ions in waste water samples by a novel zinc sensor based on a new synthesized Schiff's base

M Hosseini, SD Abkenar, MR Ganjali… - Materials Science and …, 2011 - Elsevier
A highly selective and sensitive zinc ion-selective membrane electrode based on N, N′-
phenylenebis (salicylideaminato)(L) as a new carrier is reported. The membrane is …

Potentiometric zinc ion sensor based on honeycomb-like NiO nanostructures

MA Abbasi, ZH Ibupoto, M Hussain, Y Khan, A Khan… - Sensors, 2012 - mdpi.com
In this study honeycomb-like NiO nanostructures were grown on nickel foam by a simple
hydrothermal growth method. The NiO nanostructures were characterized by field emission …

Recognition and fluorescent sensing of zinc ions using organic fluorophores-based sensor molecules

D Shi, X Zhou, T Zheng, Y Zou, S Guo, J Lv… - Journal of the Iranian …, 2015 - Springer
Fluorogenic methods in conjunction with suitable probes have emerged as preferable
modalities for the monitoring and measurement of trace metal ions. The number of new Zn …