Performance analysis of IEC 61850 sampled value process bus networks

DME Ingram, P Schaub, RR Taylor… - IEEE Transactions on …, 2012 - ieeexplore.ieee.org
Process bus networks are the next stage in the evolution of substation design, bringing
digital technology to the high-voltage switchyard. Benefits of process buses include …

Performance analysis of PTP components for IEC 61850 process bus applications

DME Ingram, P Schaub, DA Campbell… - IEEE Transactions on …, 2013 - ieeexplore.ieee.org
New substation automation applications, such as sampled value (SV) process buses and
synchrophasors, require a sampling accuracy of 1 μs or better. The Precision Time Protocol …

Quantitative assessment of fault tolerant precision timing for electricity substations

DME Ingram, P Schaub, DA Campbell… - IEEE Transactions on …, 2013 - ieeexplore.ieee.org
Advanced substation applications, such as synchrophasors and IEC 61850-9-2 sampled
value process buses, depend upon highly accurate synchronizing signals for correct …

Investigation in automatic determination of time synchronization accuracy of PTP networks with the objective of Plug-and-Work

S Schriegel, L Wisniewski - 2014 IEEE international symposium …, 2014 - ieeexplore.ieee.org
Today's information technology applies Plug-and-Play/Plug-and-Work mechanisms allowing
automatic configuration of network components or computer peripheries (USB or IP address …

Using OPNET to model and evaluate the MU performance based on IEC 61850-9-2LE

M Mekkanen, E Antila, R Virrankoski… - Procedia Computer …, 2014 - Elsevier
Abstract The growth of IEC61850-9-2 process bus as a high data rate communication
network have a great improved the capability of substation automation system (SAS). This …

Testing phasor measurement units using IEEE 1588 precision time protocol

J Amelot, G Stenbakken - 2012 Conference on Precision …, 2012 - ieeexplore.ieee.org
As the electric power grid is changing to a smarter more dynamically controlled system,
there is increasing need for measurements that show the global status of the system for wide …

[PDF][PDF] Assessment of precision timing and real-time data networks for digital substation automation

DME Ingram - 2013 - eprints.qut.edu.au
This project researched the performance of emerging digital technology for high voltage
electricity substations that significantly improves safety for staff and reduces the potential …

Reliable synchronization accuracy in ieee 1588 networks using device qualification with standard test patterns

H Flatt, S Schriegel… - 2013 IEEE International …, 2013 - ieeexplore.ieee.org
This paper presents a device qualification approach for IEEE 1588 devices. Based on
repetitive measurements within heterogeneous networks, standard stimulation data and …

Towards timely intelligence in the power grid

J Amelot, D Anand, T Nelson, G Stenbakken… - Proceedings of the 44th …, 2012 - ion.org
One of the key lessons learned from the 2003 Northeast Blackout in the United States was
the need for improved grid timing and synchronization. The problem began as an isolated …

Synchronization monitoring in IEEE1588 synchronization networks

O Ronen - 2013 IEEE International Symposium on Precision …, 2013 - ieeexplore.ieee.org
The IEEE1588-2008 (precision time protocol, PTP) is being deployed in various application
domains including domains requiring specified synchronization performance. Deploying …