Emerging Trends in Active Distribution Network Fault Detection

VA Rosero-Morillo, F Gonzalez-Longatt… - Renewable Energy …, 2025 - Elsevier
Electrical systems are constantly transforming to achieve global decarbonization and
address the climate emergency. This process involves a substantial modernization of the …

Review on renewable energy source fault characteristics analysis

T Bi, B Yang, K Jia, L Zheng, Q Liu… - CSEE Journal of Power …, 2022 - ieeexplore.ieee.org
The increase of renewable energy sources (RESs), especially wind power and photovoltaic,
is bringing different fault features to the power system compared with the traditional …

[HTML][HTML] Asymmetrical fault analysis on distribution feeders with inverter interfaced distributed generators

Y Li, D Wang - International Journal of Electrical Power & Energy …, 2021 - Elsevier
As the penetration level of the inverter interfaced distributed generators (IIDGs) increases, it
is necessary to consider the effect of the IIDG connection on fault analysis in distribution …

[PDF][PDF] Effects of distributed generations' integration to the distribution networks case study of solar power plant

A Shobole, M Baysal, M Wadi… - International Journal of …, 2017 - researchgate.net
All over the world, the Distributed Generations (DGs) integration to power system has
increased in the recent years due to economic, environmental and technical advantages …

A study on power-flow and short-circuit algorithms capable of analyzing the effect of load current on fault current using the bus impedance matrix

I Kim, RG Harley - 2016 IEEE Electrical Power and Energy …, 2016 - ieeexplore.ieee.org
In short-circuit studies, load makes difficult to determine fault current that flows in positive-,
negative-, and zero-sequence networks. Therefore, it is often ignored because the …

Steady‐state short‐circuit current calculation for internally limited inverter‐based distributed generation sources connected as current sources using the sequence …

I Kim - International Transactions on Electrical Energy …, 2019 - Wiley Online Library
When inverter‐based distributed generation (IBDG) sources with output current limited by an
internal current loop control or other control logic are connected to power system networks …

Adaptive protection scheme for a microgrid with high levels of renewable energy generation

R Shah, P Goli, W Shireen - 2018 Clemson University Power …, 2018 - ieeexplore.ieee.org
Deployment of high renewable energy based penetration in a distribution network increases
the fault current levels and therefore it becomes imperative to review the protective device …

A case study of calculating the short-circuit current of high-capacity power electronics-based distributed energy resources and loads

I Kim - 2021 24th International Conference on Electrical …, 2021 - ieeexplore.ieee.org
Since high-capacity distributed energy resources (DERs) are connected to the electric
power grid, their short-circuit current (SCC) contribution should not be neglected. That is, the …

The effect of load current on a three-phase fault

I Kim - 2016 IEEE Power & Energy Society Innovative Smart …, 2016 - ieeexplore.ieee.org
The most short-circuit studies ignore load current since the magnitude of fault current is
extremely greater than that of load current. However, as variable and intermittently …

DG integration issues in unbalanced multi-phase distribution networks

NK Roy, HR Pota, MA Mahmud - 2016 Australasian …, 2016 - ieeexplore.ieee.org
This paper analyzes positive and negative impacts of the integration of distributed
generation (DG) in unbalanced multi-phase distribution networks. Several aspects, for …