[HTML][HTML] Coded-aperture imaging systems: Past, present and future development–A review

MJ Cieślak, KAA Gamage, R Glover - Radiation Measurements, 2016 - Elsevier
Scintillator based coded-aperture imaging has proven to be effective when applied for X-and
gamma-ray detection. Adaptation of the same method for neutron imaging has resulted in a …

Rapid imaging of special nuclear materials for nuclear nonproliferation and terrorism prevention

J Petrović, A Göök, B Cederwall - Science Advances, 2021 - science.org
We introduce a neutron-gamma emission tomography (NGET) technique for rapid detection,
three-dimensional imaging, and characterization of special nuclear materials like weapons …

Imaging special nuclear material using a handheld dual particle imager

WM Steinberger, ML Ruch, N Giha, AD Fulvio… - Scientific reports, 2020 - nature.com
A compact radiation imaging system capable of detecting, localizing, and characterizing
special nuclear material (eg highly-enriched uranium, plutonium…) would be useful for …

A compact neutron scatter camera for field deployment

JEM Goldsmith, MD Gerling, JS Brennan - Review of Scientific …, 2016 - pubs.aip.org
We describe a very compact (0.9 m high, 0.4 m diameter, 40 kg) battery operable neutron
scatter camera designed for field deployment. Unlike most other systems, the configuration …

[HTML][HTML] Pulse shape discrimination using a stilbene scintillator array coupled to a large-area SiPM array for hand-held dual particle imager applications

J Boo, MD Hammig, M Jeong - Nuclear Engineering and Technology, 2023 - Elsevier
A dual-particle imager (DPI) is configured in a hand-held form factor, then one can efficiently
and conveniently deploy the DPI to detect the presence of special nuclear materials (SNM) …

Time-encoded gamma-ray imaging using a 3-D position-sensitive CdZnTe detector array

ST Brown, D Goodman, J Chu… - … on Nuclear Science, 2019 - ieeexplore.ieee.org
The gamma-ray response of thick pixelated CdZnTe detectors varies spatially but is
relatively constant as a function of time. Detector irregularities arise from flaws in the …

[PDF][PDF] The deployable fast-neutron coded-aperture imager: Demonstration of locating one or more sources in three dimensions

P Hausladen, J Newby, F Liang… - … by UT-Battelle LLC for the …, 2013 - info.ornl.gov
This brief report describes commissioning measurements performed using a newly
constructed fastneutron coded-aperture imager intended for performing quantitative …

Application of an added-sinusoid, signal-multiplexing scheme to a compact, multiplexed neutron scatter camera

MA Wonders, M Flaska - Nuclear Instruments and Methods in Physics …, 2021 - Elsevier
The development of compact and portable neutron imagers could be transformative for
nuclear nonproliferation and security. Of the currently feasible neutron imaging concepts, the …

Design and performance evaluation of a large field-of-view dual-particle time-encoded imager based on a depth-of-interaction detector

D Zhao, XW Liang, PK Cai, W Cheng, WB Jia… - Nuclear Science and …, 2024 - Springer
Time-encoded imaging is useful for identifying potential special nuclear materials and other
radioactive sources at a distance. In this study, a large field-of-view time-encoded imager …

64-element fast-neutron, coded-aperture imager

CV Griffith, RS Woolf, BF Phlips - 2017 IEEE International …, 2017 - ieeexplore.ieee.org
We report on the characterization efforts on a largescale, coded-aperture imager for fast
neutrons at the US Naval Research Laboratory. The fast neutron imager discussed in this …