Experimental studies on monitoring and metering of radial deformations on transformer HV winding using image processing and UWB transceivers

S Mortazavian, MM Shabestary… - IEEE Transactions …, 2015 - ieeexplore.ieee.org
In this paper, a novel method based on image processing is proposed for detecting the
presence and location of mechanical deformations on an actual power transformer winding …

Feasibility study on simultaneous detection of partial discharge and axial displacement of HV transformer winding using electromagnetic waves

H Karami, H Tabarsa, GB Gharehpetian… - IEEE Transactions …, 2019 - ieeexplore.ieee.org
Recently, axial displacement detection of transformer winding has been performed using
synthetic-aperture radar (SAR) imaging, as an online method, in ultra-wideband frequency …

Novel technique for location identification and estimation of extent of turn-to-turn fault in transformer winding

A Kumar, BR Bhalja… - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
This article presents a novel technique for diagnosing a turn-to-turn fault at the incipient level
inside the power transformer winding using frequency response analysis (FRA). Utilizing …

Determination of transformer winding radial deformation using UWB system and hyperboloid method

H Rahbarimagham, HK Porzani… - IEEE Sensors …, 2015 - ieeexplore.ieee.org
Online monitoring of the transformer winding using electromagnetic waves has recently
been proposed for the detection of mechanical defects of transformer winding. In this paper …

Proposed methodology for online frequency response analysis based on magnetic coupling to detect winding deformations in transformers

Y Cheng, J Bi, W Chang, Y Xu, X Pan, X Ma… - High …, 2020 - Wiley Online Library
Frequency response analysis is widely used as a method for the offline diagnosis of winding
deformations in power transformers. To apply it to a working transformer, people need to …

Identifying the Phase Undergoing a Discrete and Localized Radial Displacement in 3-, Y and Windings Using FRA: An Experimental Study

B Biswas, L Satish - IEEE Transactions on Power Delivery, 2023 - ieeexplore.ieee.org
Mechanical winding damages in transformers are quite common. Inherently these damages
at an advanced stage are very complex in appearance and are a challenge to represent …

GLRT-based mitigation of partial discharge effect on detection of radial deformation of transformer HV winding using SAR imaging method

H Karami, GB Gharehpetian, Y Norouzi… - IEEE Sensors …, 2016 - ieeexplore.ieee.org
Online and on time detection of defects leads to technical and economic merits for networks.
Recently, an online method has been introduced for the radial deformation detection of …

Detection of HV winding radial deformation and PD in power transformer using stepped-frequency hyperboloid method

H Tabarsa, MA Hejazi… - IEEE Transactions on …, 2018 - ieeexplore.ieee.org
Detection of winding deformation and partial discharge (PD) is essential for monitoring and
failure risk assessment of power transformers. Recently, an online method based on …

Simultaneous radial deformation and partial discharge detection of high‐voltage winding of power transformer

H Karami, GB Gharehpetian, Y Norouzi… - IET Electric Power …, 2020 - Wiley Online Library
Condition monitoring of power transformers has attracted a lot of attention due to their
important roles in determining power system reliability. Radial deformation of power …

Experimental study on elimination of partial discharge effect on detection of radial deformation of high voltage transformer winding using electromagnetic waves

H Karami, GB Gharehpetian, Y Norouzi… - … on Environment and …, 2018 - ieeexplore.ieee.org
Online detection of defects in power transformers attracts attention of researchers because
of its technical and economic advantages. Recently, radial deformation detection has been …