Estimating a neutral reference for electroencephalographic recordings: the importance of using a high-density montage and a realistic head model

Q Liu, JH Balsters, M Baechinger… - Journal of neural …, 2015 - iopscience.iop.org
Objective. In electroencephalography (EEG) measurements, the signal of each recording
electrode is contrasted with a reference electrode or a combination of electrodes. The …

[HTML][HTML] Automated EEG source imaging: a retrospective, blinded clinical validation study

AG Baroumand, P van Mierlo, G Strobbe… - Clinical …, 2018 - Elsevier
Objective To evaluate the accuracy of automated EEG source imaging (ESI) in localizing
epileptogenic zone. Methods Long-term EEG, recorded with the standard 25-electrode array …

Incorporating and compensating cerebrospinal fluid in surface-based forward models of magneto-and electroencephalography

M Stenroos, A Nummenmaa - PLoS One, 2016 - journals.plos.org
MEG/EEG source imaging is usually done using a three-shell (3-S) or a simpler head model.
Such models omit cerebrospinal fluid (CSF) that strongly affects the volume currents. We …

Automated ictal EEG source imaging: A retrospective, blinded clinical validation study

AG Baroumand, AA Arbune, G Strobbe… - Clinical …, 2022 - Elsevier
Objective EEG source imaging (ESI) is a validated tool in the multimodal workup of patients
with drug resistant focal epilepsy. However, it requires special expertise and it is …

Effective connectivity based EEG revealing the inhibitory deficits for distracting stimuli in major depression disorders

J Li, Y Hao, W Zhang, X Li, B Hu - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
Emotional conflict control is impaired in major depression disorders (MDDs) and affects
decision-making with further consequent social interactions dysfunction. However, neural …

A simple method for EEG guided transcranial electrical stimulation without models

A Cancelli, C Cottone, F Tecchio… - Journal of neural …, 2016 - iopscience.iop.org
Objective. There is longstanding interest in using EEG measurements to inform transcranial
Electrical Stimulation (tES) but adoption is lacking because users need a simple and …

A finite-element reciprocity solution for EEG forward modeling with realistic individual head models

E Ziegler, SL Chellappa, G Gaggioni, JQM Ly… - NeuroImage, 2014 - Elsevier
We present a finite element modeling (FEM) implementation for solving the forward problem
in electroencephalography (EEG). The solution is based on Helmholtz's principle of …

Improved EEG source localization with Bayesian uncertainty modelling of unknown skull conductivity

V Rimpiläinen, A Koulouri, F Lucka, JP Kaipio… - Neuroimage, 2019 - Elsevier
Electroencephalography (EEG) source imaging is an ill-posed inverse problem that requires
accurate conductivity modelling of the head tissues, especially the skull. Unfortunately, the …

Brain source localization using reduced EEG sensors

MA Jatoi, N Kamel - Signal, Image and video processing, 2018 - Springer
Brain source activation is caused due to certain mental or physical task, and such activation
is localized by using various optimization techniques. This localization has vital application …

The dynamic dielectric at a brain functional site and an EM wave approach to functional brain imaging

XP Li, Q Xia, D Qu, TC Wu, DG Yang, WD Hao… - Scientific reports, 2014 - nature.com
Functional brain imaging has tremendous applications. The existing methods for functional
brain imaging include functional Magnetic Resonant Imaging (fMRI), scalp …