Metrics for glycaemic control — from HbA1c to continuous glucose monitoring

BP Kovatchev - Nature Reviews Endocrinology, 2017 - nature.com
As intensive treatment to lower levels of HbA1c characteristically results in an increased risk
of hypoglycaemia, patients with diabetes mellitus face a life-long optimization problem to …

Diabetes: models, signals, and control

C Cobelli, C Dalla Man, G Sparacino… - IEEE reviews in …, 2009 - ieeexplore.ieee.org
The control of diabetes is an interdisciplinary endeavor, which includes a significant
biomedical engineering component, with traditions of success beginning in the early 1960s …

Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: a multicentre, non-masked, randomised controlled trial

J Bolinder, R Antuna, P Geelhoed-Duijvestijn, J Kröger… - The Lancet, 2016 - thelancet.com
Background Tight control of blood glucose in type 1 diabetes delays onset of macrovascular
and microvascular diabetic complications; however, glucose levels need to be closely …

A Hydrogel Microneedle Assay Combined with Nucleic Acid Probes for On‐Site Detection of Small Molecules and Proteins

F Keyvani, H Zheng, MR Kaysir… - Angewandte …, 2023 - Wiley Online Library
Point‐of‐care testing (POCT) of clinical biomarkers is critical to health monitoring and timely
treatment, yet biosensing assays capable of detecting biomarkers without the need for costly …

Recommendations for standardizing glucose reporting and analysis to optimize clinical decision making in diabetes: the Ambulatory Glucose Profile (AGP)

RM Bergenstal, AJ Ahmann, T Bailey, RW Beck… - 2013 - liebertpub.com
Underutilization of glucose data and lack of easy and standardized glucose data collection,
analysis, visualization, and guided clinical decision making are key contributors to poor …

Nocturnal glucose control with an artificial pancreas at a diabetes camp

M Phillip, T Battelino, E Atlas… - … England Journal of …, 2013 - Mass Medical Soc
Background Recent studies have shown that an artificial-pancreas system can improve
glucose control and reduce nocturnal hypoglycemia. However, it is not known whether such …

Normal reference range for mean tissue glucose and glycemic variability derived from continuous glucose monitoring for subjects without diabetes in different ethnic …

NR Hill, NS Oliver, P Choudhary, JC Levy… - Diabetes technology …, 2011 - liebertpub.com
Background: Glycemic variability has been proposed as a contributing factor in the
development of diabetes complications. Multiple measures exist to calculate the magnitude …

Metrics beyond hemoglobin A1C in diabetes management: time in range, hypoglycemia, and other parameters

LAC Wright, IB Hirsch - Diabetes technology & therapeutics, 2017 - liebertpub.com
We review clinical instances in which A1C should not be used and reflect on the use of other
glucose metrics that can be used, in substitution of or in combination with A1C and SMBG, to …

Evidence-informed clinical practice recommendations for treatment of type 1 diabetes complicated by problematic hypoglycemia

P Choudhary, MR Rickels, PA Senior… - Diabetes …, 2015 - Am Diabetes Assoc
Problematic hypoglycemia, defined as two or more episodes per year of severe
hypoglycemia or as one episode associated with impaired awareness of hypoglycemia …

[HTML][HTML] Glycemic variability: how to measure and its clinical implication for type 2 diabetes

GE Umpierrez, BP Kovatchev - The American journal of the medical …, 2018 - Elsevier
Glycated hemoglobin A 1c (A1C) levels have traditionally been the gold standard for
assessing glycemic control and treatment efficacy in patients with type 2 diabetes. However …