Passivity-based stability assessment of grid-connected VSCs—An overview

L Harnefors, X Wang, AG Yepes… - IEEE Journal of …, 2015 - ieeexplore.ieee.org
The interconnection stability of a grid-connected voltage-source converter (VSC) can be
assessed by the passivity properties of the VSC input admittance. If critical grid resonances …

A comprehensive survey on fault tolerance in multiphase ac drives, Part 1: General overview considering multiple fault types

AG Yepes, O Lopez, I Gonzalez-Prieto, MJ Duran… - Machines, 2022 - mdpi.com
Multiphase drives offer enhanced fault-tolerant capabilities compared with conventional
three-phase ones. Their phase redundancy makes them able to continue running in the …

Passivity-based controller design of grid-connected VSCs for prevention of electrical resonance instability

L Harnefors, AG Yepes, A Vidal… - IEEE Transactions on …, 2014 - ieeexplore.ieee.org
The time delay in the current control loop of a grid-connected voltage-source converter
(VSC) may cause destabilization of electrical resonances in the grid or in the VSC's input …

Dynamic analysis of modular multilevel converters

L Harnefors, A Antonopoulos, S Norrga… - IEEE Transactions …, 2012 - ieeexplore.ieee.org
Theory for the dynamics of modular multilevel converters is developed in this paper. It is
shown that the sum capacitor voltage in each arm often can be considered instead of the …

Advanced vector control for voltage source converters connected to weak grids

A Egea-Alvarez, S Fekriasl, F Hassan… - … on Power Systems, 2015 - ieeexplore.ieee.org
This paper addresses an advanced vector current control for a voltage source converter
(VSC) connected to a weak grid. The proposed control methodology permits high …

Input-admittance calculation and shaping for controlled voltage-source converters

L Harnefors, M Bongiorno… - IEEE transactions on …, 2007 - ieeexplore.ieee.org
A controlled power electronic converter can cause local instabilities when interacting with
other dynamic subsystems in a power system. Oscillations at a certain frequency cannot …

Deep learning-based long-horizon MPC: robust, high performing, and computationally efficient control for PMSM drives

M Abu-Ali, F Berkel, M Manderla… - IEEE transactions on …, 2022 - ieeexplore.ieee.org
This article presents a computationally efficient and high performing approximate long-
horizon model predictive control (MPC) for permanent magnet synchronous motors …

Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip

J Morren, SWH De Haan - IEEE Transactions on energy …, 2005 - ieeexplore.ieee.org
In this paper, a solution is described that makes it possible for wind turbines using doubly-
fed induction generators to stay connected to the grid during grid faults. The key of the …

Frequency domain analysis of three phase linear current regulators

DN Zmood, DG Holmes, G Bode - Conference Record of the …, 1999 - ieeexplore.ieee.org
Stationary frame linear PI current regulators are conventionally regarded as unsatisfactory
for AC systems because they cannot eliminate steady state errors. Consequently …

A universal controller for grid-connected voltage-source converters

L Harnefors, J Kukkola, M Routimo… - IEEE Journal of …, 2020 - ieeexplore.ieee.org
The power-synchronization control (PSC) and vector current control (VCC), the latter
including cascaded outer loops, are, respectively, considered to be grid-forming and grid …