[PDF][PDF] The accuracy of the Acuros XB algorithm in external beam radiotherapy–a comprehensive review

J Ojala - Int J Cancer Ther Oncol, 2014 - core.ac.uk
The accuracy of dose calculation algorithms has been a topic of interest among the
radiotherapy community throughout last decades. On one hand the advancements in …

[PDF][PDF] Clinical dosimetric impact of Acuros XB and analytical anisotropic algorithm (AAA) on real lung cancer treatment plans

S Rana - International Journal of Cancer Therapy and Oncology, 2014 - core.ac.uk
Photon dose calculation algorithms in treatment planning system could affect the accuracy of
dose delivery when tissue heterogeneity is involved along the beam path. Treatment …

Deep inspiration breath-hold for left-sided breast irradiation: analysis of dose-mass histograms and the impact of lung expansion

M Oechsner, M Düsberg, KJ Borm, SE Combs… - Radiation …, 2019 - Springer
Background The aim of this study was to compare dose-volume histogram (DVH) with dose-
mass histogram (DMH) parameters for treatment of left-sided breast cancer in deep …

Dose calculation of Acuros XB and Anisotropic Analytical Algorithm in lung stereotactic body radiotherapy treatment with flattening filter free beams and the potential …

B Huang, L Wu, P Lin, C Chen - Radiation oncology, 2015 - Springer
Background The study aimed to appraise the dose differences between Acuros XB (AXB)
and Anisotropic Analytical Algorithm (AAA) in stereotactic body radiotherapy (SBRT) …

A dosimetric comparison of three‐dimensional conformal radiotherapy, volumetric‐modulated arc therapy, and dynamic conformal arc therapy in the treatment of non …

BM Rauschenbach, L Mackowiak… - Journal of applied …, 2014 - Wiley Online Library
This study evaluates three‐dimensional conformal radiotherapy (3D CRT), volumetric‐
modulated arc therapy (VMAT), and dynamic conformal arc therapy (DCAT) planning …

Calculation of absorbed dose in radiotherapy by solution of the linear Boltzmann transport equations

JL Bedford - Physics in Medicine & Biology, 2019 - iopscience.iop.org
Over the last decade, dose calculations which solve the linear Boltzmann transport
equations have been introduced into clinical practice and are now in widespread use …

End‐to‐end verification of an MR‐Linac using a dynamic motion phantom

X Liu, C Li, J Zhu, G Gong, H Sun, X Li, M Sun… - Medical …, 2021 - Wiley Online Library
Purpose MR‐Linac integrates an MRI scanner and a linear accelerator to provide adaptive
radiation treatment. Superior tissue contrast and real‐time imaging can give the clinicians …

[HTML][HTML] Dosimetric impact of Acuros XB dose-to-water and dose-to-medium reporting modes on lung stereotactic body radiation therapy and its dependency on …

C Muñoz-Montplet, R Fuentes-Raspall… - Advances in Radiation …, 2021 - Elsevier
Purpose To assess the dosimetric impact of switching from the analytical anisotropic
algorithm (AAA) to Acuros XB (AXB), with dose-to-medium (Dm) and dose-to-water (Dw) …

Comparison of dosimetric accuracy of acuros XB and analytical anisotropic algorithm against Monte Carlo technique

B Seniwal, CP Bhatt, TCF Fonseca - Biomedical Physics & …, 2020 - iopscience.iop.org
This study reports the comparison between two dose calculation algorithms, Acuros XB 13.5
(AXB) and Analytical Anisotropic Algorithm (AAA) against Monte Carlo (MC) simulations for …

On the use of AAA and AcurosXB algorithms for three different stereotactic ablative body radiotherapy (SABR) techniques: Volumetric modulated arc therapy (VMAT) …

A Tajaldeen, P Ramachandran… - Reports of Practical …, 2019 - journals.viamedica.pl
Aim The purpose of this study was to investigate the dosimetric characteristics of three
stereotactic ablative body radiotherapy (SABR) techniques using the anisotropic analytical …