Relation between blood pressure and pulse wave velocity for human arteries

Y Ma, J Choi, A Hourlier-Fargette… - Proceedings of the …, 2018 - National Acad Sciences
Continuous monitoring of blood pressure, an essential measure of health status, typically
requires complex, costly, and invasive techniques that can expose patients to risks of …

[HTML][HTML] Enhancing cardiovascular health monitoring: Simultaneous multi-artery cardiac markers recording with flexible and bio-compatible AlN piezoelectric sensors

M Cinquino, SM Demir, AT Shumba… - Biosensors and …, 2025 - Elsevier
Continuous monitoring of cardiovascular parameters like pulse wave velocity (PWV), blood
pressure wave (BPW), stiffness index (SI), reflection index (RI), mean arterial pressure …

Low operating voltage and highly pressure-sensitive printed sensor for healthcare monitoring with analogic amplifier circuit

T Sekine, A Gaı̈tis, J Sato, K Miyazawa… - ACS Applied …, 2019 - ACS Publications
Flexible printed analogic amplifier circuits are required in wearable sensors to enhance their
sensitivity for application in various fields such as healthcare, artificial skins, and soft …

Method for Inkjet-printing PEDOT: PSS polymer electrode arrays on piezoelectric PVDF-TrFE fibers

A Closson, H Richards, Z Xu, C Jin, L Dong… - IEEE sensors …, 2021 - ieeexplore.ieee.org
We present a method for printing conductive polymers onto P (VDF-TrFE) nanofibers to
create all-polymer piezoelectric devices. Inkjet printing is an attractive fabrication approach …

Assessment of a calibration-free method of cuffless blood pressure measurement: A pilot study

CY Guo, CC Chang, KJ Wang… - IEEE Journal of …, 2022 - ieeexplore.ieee.org
This study proposes a low-cost, high-sensitivity sensor of beat-to-beat local pulse wave
velocity (PWV), to be used in a cuffless blood pressure monitor (BPM). Objective: We design …

Piezoelectric sensor for the monitoring of arterial pulse wave: Detection of arrhythmia occurring in PAC/PVC patients

CY Guo, KJ Wang, TL Hsieh - Sensors, 2021 - mdpi.com
Previous studies have found that the non-invasive blood pressure measurement method
based on the oscillometric method is inaccurate when an arrhythmia occurs. Therefore, we …

A multi-functional physiological hybrid-sensing E-skin integrated interface for wearable IoT applications

K Lee, HY Chae, K Park, Y Lee, S Cho… - IEEE transactions on …, 2019 - ieeexplore.ieee.org
This paper presents a flexible multi-functional physiological sensing system that provides
multiple noise-immune readout architectures and hybrid-sensing capability with an analog …

Design of pulse and respiration monitoring system based on fiber optic sensing and VMD-FPR processing algorithm

S Taoping, L Zhichao - Optical Fiber Technology, 2022 - Elsevier
We propose a pulse and respiration monitoring system based on fiber optic sensing, to
achieve accurate monitoring of human pulse and respiration rate with wearable and high …

Bionanomaterial thin film for piezoelectric applications

MHM Akmal, FB Ahmad - Advances in Nanotechnology and Its …, 2020 - Springer
Wearable and flexible electronics are recently gaining interest due to the expansion of
Internet of things (IoT). Thin-film piezoelectric materials have the potential to be used in the …

Wearable Sensors for Vital Signs: A Review of 20 Years in BioCAS and Future Directions

Y Suo, Y Zhao, Y Lian - 2024 IEEE Biomedical Circuits and …, 2024 - ieeexplore.ieee.org
This paper presents a comprehensive review of the advancements of wearables over 20
years of BioCAS and explores future directions in the field. The review focuses on the …