[HTML][HTML] A review of key components of hydrogen recirculation subsystem for fuel cell vehicles

J Han, J Feng, P Chen, Y Liu, X Peng - Energy Conversion and …, 2022 - Elsevier
Hydrogen energy and fuel cell technology are critical clean energy roads to pursue carbon
neutrality. The proton exchange membrane fuel cell (PEMFC) has a wide range of …

[HTML][HTML] Thermal performance and emissions analysis of a new cooling tower prototype

J Ruiz, P Navarro, M Hernández, M Lucas… - Applied Thermal …, 2022 - Elsevier
The design of a wet cooling tower involves a number of trade-offs including the efficiency of
the device to remove waste heat (thermal performance) and environmental aspects …

Water recovery efficiency improvement using the enhanced structure of the mist eliminator

Z Yu, C Sun, J Fang, L Zhang, Y Hu, B Bao, S Bu… - Process Safety and …, 2021 - Elsevier
Thermal power plants are users of high water consumption, and the water consumption of
cooling towers accounts for more than half of the total water consumption of the whole plant …

A novel drift eliminator enhanced by Voronoi-based porous foam applied to liquid desiccant system: Separation performance and preliminary design

B Cao, Y Yin, X Zhao, F Qian - Building and Environment, 2022 - Elsevier
A novel drift eliminator enhanced by Voronoi-based porous foam (VPF-enhanced drift
eliminator) is proposed for the control of salt-spray aerosol in liquid desiccant systems. The …

Numerical analysis of chevron demisters with drainage hooks in optimizing separation performance

S Li, P Wang, X Luo, Y Wang, X Yang… - International Journal of …, 2020 - Elsevier
Chevron demister is widely used in the industry program to remove the liquid droplets from
gas flow. Design a demister with optimal separation performance (higher separation …

Experimental study of an ultrasonic mist generator as an evaporative cooler

P Martinez, J Ruiz, Í Martín, M Lucas - Applied Thermal Engineering, 2020 - Elsevier
This paper presents an ultrasonic mist generator used as an evaporative pre-cooler for air-
cooled condensers in air conditioning applications. Ultrasonic mist generators eliminate …

Research on water droplet interception mechanism of sheet-type drift eliminator based on three-dimensional transient numerical simulation

X Zhang, F Sun, X Chen - Energy, 2024 - Elsevier
A three-dimensional transient numerical study was conducted on the sheet-type drift
eliminator single-channel to reveal the droplet interception mechanism, using a mechanical …

[HTML][HTML] Numerical study of an ultrasonic spray atomiser as an evaporative cooler

P Navarro, J Ruiz, P Martínez, M Lucas - Applied Thermal Engineering, 2024 - Elsevier
Pre-cooling the inlet air of an air conditioning condenser through evaporative cooling has
proven highly effective in enhancing performance. Previous works focused on utilising an …

Experimental study of pressure loss in hybrid cooling tower with finned tube radiator

VV Kharkov, IN Madyshev, MG Kuznetsov… - Journal of Physics …, 2022 - iopscience.iop.org
The paper deals with the problem of enhancement of cooling of recycled water in industry.
The authors developed a new design of a hybrid cooling tower with a fill pack consisting of …

Numerical characterization of an ultrasonic mist generator as an evaporative cooler

J Ruiz, P Martínez, Í Martín, M Lucas - Energies, 2020 - mdpi.com
Pre-cooling of inlet air using evaporative cooling is an effective approach to enhance the
performance of air-cooled condensers in air conditioning applications. Ultrasonic mist …