Power line communication technologies for smart grid applications: A review of advances and challenges

M Yigit, VC Gungor, G Tuna, M Rangoussi, E Fadel - Computer Networks, 2014 - Elsevier
This paper investigates the use of Power Line Communication (PLC) for Smart Grid (SG)
applications. Firstly, an overview is done to define the characteristics of PLC and PLC-based …

[HTML][HTML] A review on the empirical characterization of the low voltage distribution grid as a communication channel for power line communications

J González-Ramos, A Gallarreta, I Angulo… - … Energy, Grids and …, 2023 - Elsevier
The electrical grid was not designed for the transmission of communication signals, which
are affected by impedance variations, attenuation, and Non-Intentional Emissions (NIEs) in …

Deep clipping for impulsive noise mitigation in OFDM-based power-line communications

FH Juwono, Q Guo, D Huang… - IEEE Transactions on …, 2014 - ieeexplore.ieee.org
Nonlinear preprocessors, including clipping, blanking, and joint blanking/clipping have been
proposed to be employed in orthogonal frequency-division multiplexing systems for …

Modelling impulsive noise in indoor powerline communication systems

O Karakuş, EE Kuruoğlu, MA Altınkaya - Signal, image and video …, 2020 - Springer
Powerline communication (PLC) is an emerging technology that has an important role in
smart grid systems. Due to making use of existing transmission lines for communication …

Iterative channel estimation and impulsive noise mitigation algorithm for OFDM-based receivers with application to power-line communications

YR Chien - IEEE Transactions on Power Delivery, 2015 - ieeexplore.ieee.org
This paper presents a novel iterative receiver used to mitigate the impact of impulsive noise
(IN) on orthogonal frequency-division multiplexing (OFDM)-based baseband power-line …

DC power line communication (PLC) on 868 MHz and 2.4 GHz wired RF transceivers

V Marsic, T Amietszajew, P Igic, S Faramehr, J Fleming - Sensors, 2022 - mdpi.com
Efficient management through monitoring of Li-ion batteries is critical to the progress of
electro-mobility and energy storage globally, since the technology can be hazardous if …

An optimal interleaving scheme with maximum time-frequency diversity for PLC systems

S Liu, F Yang, J Song - IEEE Transactions on Power Delivery, 2014 - ieeexplore.ieee.org
In this paper, an optimal interleaving scheme with maximum time-frequency diversity is
proposed to combat against the narrowband interference (NBI) and time-domain impulsive …

Comparison of measurement methods of LV grid access impedance in the frequency range assigned to Nb‑Plc technologies

I Fernández, D de la Vega, D Roggo, R Stiegler… - Electronics, 2019 - mdpi.com
The paper presents and evaluates three advanced methods for the characterization of the
low-voltage (LV) grid access impedance for the frequency range assigned to Narrow Band …

The impact of statistical noise modeling on the error-rate performance of OFDM power-line communications

F Gianaroli, F Pancaldi… - IEEE Transactions on …, 2014 - ieeexplore.ieee.org
In this paper, the impact of statistical noise modelling on the error performance achieved by
orthogonal frequency-division multiplexing (OFDM) over indoor broadband power-line …

On the use of Zadeh's series expansion for modeling and estimation of indoor powerline channels

F Gianaroli, F Pancaldi… - IEEE transactions on …, 2014 - ieeexplore.ieee.org
Indoor powerline channels usually exhibit a cyclic input-output behavior due to the time-
varying impedance of power loads. This makes typical time-invariant system models …