WoodST: A Temperature-Dependent Plastic-Damage Constitutive Model Used for Numerical Simulation of Wood-Based Materials and Connections

Z Chen, C Ni, C Dagenais, S Kuan - Journal of Structural …, 2020 - ascelibrary.org
The thermomechanical behavior of members and connections plays a crucial role in the fire
safety of timber construction. In this study, a unique constitutive model, Wood ST, combining …

Experimental and numerical investigation into the fire performance of glulam bolted beam-to-column connections under coupled moment and shear force

J Luo, M He, Z Li, Z Gan, X Wang, F Liang - Journal of Building Engineering, 2022 - Elsevier
The fire resistance of connection plays a crucial role in the fire performance of timber
structures. During the past three decades, massive real-scale fire tests were performed on …

Review of experimental data for timber connections with dowel-type fasteners under standard fire exposure

M Audebert, D Dhima, A Bouchaïr, A Frangi - Fire Safety Journal, 2019 - Elsevier
This paper presents a summary of experimental results from various studies conducted
these twenty last years on the behaviour of steel-to-timber or timber-to-timber connections …

Sequentially coupled thermal-stress analysis of traditional timber mortise-tenon joints with damage

X Song, Y Lu, Y Peng, Y Zhang, H Zhou - Journal of Building Engineering, 2024 - Elsevier
This paper presents the results of the fire resistance of traditional timber mortise-tenon joints
with service damage. Static loading and fire resistance tests were conducted with full scale …

Analytical investigation and parametric study on the fire behavior of glulam bolted beam-to-column connections based on the quasi-non-linear fracture mechanics …

J Luo, Z Li, M He, Z Gan, X Wang - Fire Safety Journal, 2022 - Elsevier
In this study, an analytical approach is developed to estimate the fire resistance of glulam
bolted connections under coupled shear force and bending moment. This approach …

Probabilistic model for determining the failure time of steel-to-timber connections with multiple dowel-type fasteners exposed to fire

ACM Júnior, PD de Moraes - Fire safety journal, 2022 - Elsevier
There is a lack of knowledge on the structural reliability of dowel-type connections exposed
to fire. The objective of this paper is to propose a model for the structural reliability analysis …

Fire Testing of Glue-Laminated Beam-to-Column Connections

EC Fischer, S Bhandari, A Sinha - Journal of Structural Engineering, 2025 - ascelibrary.org
Mass timber is increasing in popularity all over the world due to the advantages such as
shorter erection time and lower carbon footprint. However, unlike other commonly used …

Simplified design method for fire resistance of timber connections

M Audebert, D Dhima, A Bouchaïr… - Journal of Structural …, 2021 - ascelibrary.org
Since 1999, a long research program has been underway in France with the aim of better
understanding the mechanical behavior of timber connections in fire situations. This work …

Analytical Model for Non-linear $$\user2 {M-}\,\,{\varvec {\theta}} $$ Relationships of Dowel-Type Timber Connections Exposed to Fire

Y Nakayama, T Kikuchi, M Totsuka, T Hirashima - Fire Technology, 2024 - Springer
Recent experimental evidence has shown that wood–steel–wood dowel-type connections
exhibit a semi-rigid behaviour even after 90 min of fire exposure. Because a semi-rigid …

Fire tests of steel‐to‐timber connections with high fire resistance

D Dhima, M Audebert, A Bouchaïr… - Fire and …, 2023 - Wiley Online Library
This paper presents the results of twenty‐one fire tests on unprotected steel‐to‐timber
connections with dowel‐type fasteners and one or two slotted‐in steel plates. The …