A review of arterial phantom fabrication methods for flow measurement using PIV techniques

SG Yazdi, PH Geoghegan, PD Docherty… - Annals of Biomedical …, 2018 - Springer
Cardiovascular diseases (CVD) are the leading cause of morbidity and mortality in the
western world. In the last three decades, fluid dynamics investigations have been an …

High shear stress induces atherosclerotic vulnerable plaque formation through angiogenesis

Y Wang, J Qiu, S Luo, X Xie, Y Zheng… - Regenerative …, 2016 - academic.oup.com
Rupture of atherosclerotic plaques causing thrombosis is the main cause of acute coronary
syndrome and ischemic strokes. Inhibition of thrombosis is one of the important tasks …

Heart rate: a forgotten link in coronary artery disease?

KM Fox, R Ferrari - Nature reviews cardiology, 2011 - nature.com
A considerable body of evidence indicates that elevated resting heart rate is an
independent, modifiable risk factor for cardiovascular events and mortality in patients with …

Computer aided diagnosis of coronary artery disease, myocardial infarction and carotid atherosclerosis using ultrasound images: a review

O Faust, UR Acharya, VK Sudarshan, R San Tan… - Physica Medica, 2017 - Elsevier
Abstract The diagnosis of Coronary Artery Disease (CAD), Myocardial Infarction (MI) and
carotid atherosclerosis is of paramount importance, as these cardiovascular diseases may …

Tortuosity triggers platelet activation and thrombus formation in microvessels

JKW Chesnutt, HC Han - 2011 - asmedigitalcollection.asme.org
Tortuous blood vessels are often seen in humans in association with thrombosis,
atherosclerosis, hypertension, and aging. Vessel tortuosity can cause high fluid shear stress …

Blood flow through sutured and coupled microvascular anastomoses: a comparative computational study

RAJ Wain, JPM Whitty, MD Dalal, MC Holmes… - Journal of Plastic …, 2014 - Elsevier
This study uses computational fluid dynamics (CFD) to model blood flow through idealised
sutured and coupled arterial anastomoses to investigate the affect of each technique on …

Non‐Newtonian Effects of Blood Flow on Hemodynamics in Pulmonary Stenosis: Numerical Simulation

F He, X Wang, L Hua, T Guo - Applied Bionics and …, 2023 - Wiley Online Library
This paper aims to explore the construction of an individualized pulmonary artery stenosis
model based on computed tomography (CT) images. The stenosis model is simulated using …

Non‐newtonian blood flow simulation of diastolic phase in bileaflet mechanical heart valve implanted in a realistic aortic root containing coronary arteries

P Hanafizadeh, N Mirkhani, MR Davoudi… - Artificial …, 2016 - Wiley Online Library
Coronary arteries, which are branched from the sinuses, have tangible effects on the
hemodynamic performance of the bileaflet mechanical heart valve (BMHV), especially in the …

Cantilever snap-fit performance analysis for haptic evaluation

J Ji, KM Lee, S Zhang - 2011 - asmedigitalcollection.asme.org
This paper investigates the parametric effects, which include material properties, hook
shape, and shear deformation, on the force/deflection relationship governing the …

Ivabradine: potential clinical applications in critically ill patients

V De Santis, D Vitale, A Santoro, A Magliocca… - Clinical Research in …, 2013 - Springer
It has been extensively demonstrated that an elevated heart rate is a modifiable,
independent risk factor for cardiovascular events. A high heart rate increases myocardial …