SCAI consensus document on occupational radiation exposure to the pregnant cardiologist and technical personnel

PJM Best, KA Skelding, R Mehran, A Chieffo… - Heart, Lung and …, 2011 - Elsevier
Concerns regarding radiation exposure and its effects during pregnancy are often quoted as
an important barrier preventing many women from pursuing a career in Interventional …

ICRP publication 121: radiological protection in paediatric diagnostic and interventional radiology

PL Khong, H Ringertz, V Donoghue, D Frush… - Annals of the ICRP, 2013 - Elsevier
Paediatric patients have a higher average risk of developing cancer compared with adults
receiving the same dose. The longer life expectancy in children allows more time for any …

[HTML][HTML] Practice of ALARA in the pediatric interventional suite

B Connolly, J Racadio, R Towbin - Pediatric radiology, 2006 - Springer
As interventional procedures have become progressively more sophisticated and lengthy,
the potential for high patient radiation dose has increased. Staff exposure arises from patient …

An investigation of operator exposure in interventional radiology

BA Schueler, TJ Vrieze, H Bjarnason, AW Stanson - Radiographics, 2006 - pubs.rsna.org
A study was conducted to investigate how operator exposure in interventional radiology is
affected by various common fluoroscopic imaging conditions. Stray radiation levels …

Radiation exposure to patient and staff in hepatic chemoembolization: risk estimation of cancer and deterministic effects

N Hidajat, P Wust, R Felix, RJ Schröder - … and interventional radiology, 2006 - Springer
The purpose of the study was to determine the risks of radiation-induced cancer and
deterministic effects for the patient and staff in transarterial chemoembolization (TACE) of …

[HTML][HTML] Defining the radiation “scatter cloud” in the interventional suite

OP Haqqani, PK Agarwal, NM Halin… - Journal of vascular surgery, 2013 - Elsevier
Objective We hypothesized that fluoroscopic imaging creates radiation fields that are
unevenly scattered throughout the endovascular suite. We sought to quantify the radiation …

Radiation exposure to the primary operator during endovascular surgical neuroradiology procedures

KF Layton, DF Kallmes, HJ Cloft… - American Journal …, 2006 - Am Soc Neuroradiology
Endovascular surgical neuroradiologists can receive a substantial amount of occupational
radiation exposure. We evaluated the amount of radiation exposure that results from the …

Evaluation of vascular and interventional procedures with time–action analysis: a pilot study

NH Bakker, D Tanase, JA Reekers… - Journal of vascular and …, 2002 - Elsevier
PURPOSE: To provide an objective method to measure the efficiency of vascular and
interventional procedures. MATERIALS AND METHODS: The time–action analysis method …

Radiation exposure to operators during vertebroplasty

A Komemushi, N Tanigawa, S Kariya, H Kojima… - Journal of vascular and …, 2005 - Elsevier
PURPOSE: To measure the radiation received by physicians during percutaneous
vertebroplasty with use of two types of injection devices with the interventional equipment …

[图书][B] Cardiovascular catheterization and intervention: a textbook of coronary, peripheral, and structural heart disease

D Mukherjee, E Bates, M Roffi, D Moliterno - 2010 - books.google.com
The field of invasive and interventional cardiology is dynamic with frequent advances in both