Dynamic characteristics of particulate matter resuspension due to human activities in indoor environments: a comprehensive review

F Yuan, R Yao, W Yu, S Sadrizadeh, H Awbi… - Journal of Building …, 2023 - Elsevier
Particulate matter (PM) resuspension from indoor surfaces is one of the leading causes of
occupant exposure to PM. It has been recognized as a main source of indoor air pollution by …

A review of wake effects on worker exposure

MR Flynn, B Ljungqvist - The Annals of Occupational Hygiene, 1995 - Elsevier
Boundary layer separation leads to the formation of a wake region downstream of a worker
in an air flow field. This fundamental phenomenon is responsible in many cases for …

The significance and characteristics of the personal activity cloud on exposure assessment measurements for indoor contaminants

CE Rodes, RM Kamens, RW Wiener - Indoor Air, 1991 - Wiley Online Library
The influence of personal activity sources on exposure to indoor contaminants is defined
and demonstrated using data from occupational and residential studies. The ratios of …

Personal exposure to contaminant sources in ventilated rooms

H Brohus - 1997 - vbn.aau.dk
Three different tools for personal exposure assessment are presented. They are all able to
consider the local influence of persons in ventilated rooms where concentration gradients …

Airflow pattern around a worker in a uniform freestream

T Kim, MR Flynn - American Industrial Hygiene Association Journal, 1991 - Taylor & Francis
The effect of boundary layer separation on worker exposure is an important factor in the
design of local exhaust ventilation. Three-dimensional airflow around a mannequin is …

[图书][B] Industrial hygiene control of airborne chemical hazards

W Popendorf - 2019 - taylorfrancis.com
Are you a practicing occupational hygienist wondering how to find a substitute organic
solvent that is safer to use than the hazardous one your company is using? Chapter 6 is your …

The effect of contaminant source location on worker exposure in the near-wake region

I Kulmala, A Säämänen, S Enbom - The Annals of occupational hygiene, 1996 - Elsevier
The exposure of workers in the near-wake region due to a recirculating airflow was studied
experimentally and numerically. A mannequin was installed in an open-ended tunnel and …

A smoke visualisation technique for wake flow from a moving human manikin

K Inthavong, Y Tao, P Petersen, K Mohanarangam… - Journal of …, 2017 - Springer
An experimental technique using the chemical reaction between acetic acid (CH 3 COOH)
and cyclohexylamine (C 6 H 13 N) generated smoke to visualise wake flow from a moving …

A model to estimate worker exposure to spray paint mists

GN Carlton, MR Flynn - Applied Occupational and Environmental …, 1997 - Taylor & Francis
Exposure models traditionally have emphasized the statistical association between process
parameters and measured exposures. These empirical-statistical models can identify factors …

Experimental investigation of the concept of a 'breathing zone'using a mannequin exposed to a point source of inertial/sedimenting particles emitted with momentum

G Lidén, J Waher - Annals of occupational hygiene, 2010 - academic.oup.com
An inhaling mannequin, CALTOOL, was used in a specially ventilated room to compare the
concentrations inhaled with those sampled by samplers mounted across the breathing zone …