Digital pulse deconvolution with adaptive shaping for real-time high-resolution high-throughput gamma spectroscopy

S Saxena, AI Hawari - Nuclear Instruments and Methods in Physics …, 2020 - Elsevier
A high-resolution high-throughput real-time adaptive digital pulse processing system is
developed for high count rate gamma-ray spectroscopy applications. The adaptive digital …

High-Purity Germanium Spectroscopy at Rates in Excess of Events/s

BA VanDevender, MP Dion, JE Fast… - … on Nuclear Science, 2014 - ieeexplore.ieee.org
In gamma spectroscopy, a compromise must be made between energy resolution and event-
rate capability. Some foreseen nuclear material safeguards applications require a …

Sparse Regression Algorithm for Activity Estimation in Spectrometry

Y Sepulcre, T Trigano, Y Ritov - IEEE Transactions on Signal …, 2013 - ieeexplore.ieee.org
We consider the counting rate estimation of an unknown radioactive source, which emits
photons at times modeled by an homogeneous Poisson process. A spectrometer converts …

HPGe/BGO Compton suppression system: Monte Carlo study of radiation monitoring system for failed fuel detection in sodium-cooled fast reactors

S Garti, R Coulon - Applied Radiation and Isotopes, 2021 - Elsevier
A bstract Fuel failures detection and monitoring is a key issue in sodium-cooled fast reactor
operation. This detection is based on monitoring the signal of fission products using …

[图书][B] Adaptive Digital Pulse Processing for Real-time High-throughput High-resolution Gamma-ray Spectrometry

S Saxena - 2019 - search.proquest.com
A high-resolution high-throughput real-time adaptive digital pulse processing system is
developed for high count rate applications. High count rate applications in spent nuclear fuel …

Performance of the Ultra-High Rate Germanium (UHRGe) System

JE Fast, MP Dion, DC Rodriguez, BA VanDevender… - 2013 - osti.gov
This report describes the final performance achieved with the detector system developed for
the Ultra High Rate Germanium (UHRGe) project. The system performance has been …

Transformées stabilisatrices de variance pour l'estimation de l'intensité du Shot Noise: application à l'estimation du flux neutronique

T Montagu - 2024 - theses.hal.science
Le Shot Noise est un processus aléatoire qui permet notamment de modéliser fidèlement le
nombre d'occurrences des interactions entre particules physiques et leurs détecteurs …

ADONIS, high count-rate HP-Ge γ spectrometry algorithm: Irradiated fuel assembly measurement

P Pin, E Barat, T Dautremer, T Montagu… - … on Advancements in …, 2011 - ieeexplore.ieee.org
ADONIS is a digital system for gamma-ray spectrometry, developed by CEA. This system
achieves high count-rate gamma-ray spectrometry with correct dynamic dead-time …

Performance of ADONIS-LYNX system for burn-up measurement applications at AREVA NC La Hague reprocessing plant

E Barat, S Normand, T Dautremer… - … on Advancements in …, 2013 - ieeexplore.ieee.org
This work deals with the last measurement campaign done at the AREVA NC La Hague
reprocessing plant with the new industrial ADONIS system called ADONIS LYNX. In this …

Generation-IV reactor coolant monitoring using ADONIS gamma-rays spectrometer

R Coulon, S Normand, F Lainé - 2013 - osti.gov
ADONIS is an advanced gamma-ray spectrometer using HPGe detectors and an innovating
signal processing. ADONIS is able to perform an on-line measurement in a huge radiation …