Inductor Selection, Improved Active Damping, and Speed Sensorless Operation Without Voltage Sensors in IM Drive With LC Filter

N Vaishnav, NK Bajjuri, AK Jain - IEEE Transactions on Power …, 2022 - ieeexplore.ieee.org
Owing to the phase delay and resonance oscillations introduced by the LC filter connected
in-between the voltage-source inverter (VSI) and the induction motor (IM), the “L” and “C” …

Stabilizing sets of current PI controllers for IM drives with and without LC filter

N Vaishnav, AK Jain - IEEE Transactions on Energy Conversion, 2021 - ieeexplore.ieee.org
Connection of an LC filter to the output of voltage source inverter (VSI) in squirrel cage
induction motor (SQIM) drive converts the pulse-width modulated (PWM) voltages into …

Reactive power flow in induction motor drive with inverter output sinusoidal filter and its influence on wide frequency operation

N Vaishnav, AK Jain - IEEE Transactions on Energy Conversion, 2022 - ieeexplore.ieee.org
This paper presents the reactive power flow and its influence on the wide-frequency
operation of sinusoidal filter-equipped induction motor (SFE-IM) drives. A sinusoidal filter …

Limitations in Inner-Loop PI Controllers in IM Drive With an Filter and Its Remedies

N Vaishnav, AK Jain - IEEE Transactions on Industry …, 2022 - ieeexplore.ieee.org
This article presents the proportional–integral (PI) controller design, its limitation, and
remedies for-axis currents in a vector-controlled voltage-source-inverter-fed induction motor …

Influence of Delays on Digitally Controlled IM Drive with Inverter Output LC Filter

N Vaishnav, AK Jain - 2022 IEEE 16th International Conference …, 2022 - ieeexplore.ieee.org
This paper presents the influence of delays on closed-loop control of digitally-controlled
induction motor (IM) systems with an inverter output LC filter. The delays are inevitable in a …

Limitations in inner-loop PI controller for induction motor drive with an LC filter & its remedies

N Vaishnav, AK Jain - … on Power Electronics, Drives and Energy …, 2020 - ieeexplore.ieee.org
An LC filter placed in-between a voltage source inverter (VSI) and an induction motor (IM)
introduces resonance frequency oscillations in filtered voltage and, at times, leads to close …

[PDF][PDF] Modelling, Measurement and Control A

R Mishra, TK Saha - Journal homepage: http://iieta. org/Journals/MMC …, 2018 - iieta.org
This paper presents flexible control strategy of a squirrel cage induction generator (SCIG)
featuring transition between stand-alone and grid-connected systems. The consistent load …