Measurement of the anomalous precession frequency of the muon in the Fermilab Muon Experiment

T Albahri, A Anastasi, A Anisenkov, K Badgley… - Physical Review D, 2021 - APS
The Muon g-2 Experiment at Fermi National Accelerator Laboratory (FNAL) has measured
the muon anomalous precession frequency ω am to an uncertainty of 434 parts per billion …

Detailed report on the measurement of the positive muon anomalous magnetic moment to 0.20 ppm

DP Aguillard, T Albahri, D Allspach, A Anisenkov… - Physical Review D, 2024 - APS
We present details on a new measurement of the muon magnetic anomaly, a μ=(g μ-2)/2.
The result is based on positive muon data taken at Fermilab's Muon Campus during the …

The laser-based gain monitoring system of the calorimeters in the Muon g− 2 Experiment at Fermilab

A Anastasi, A Basti, F Bedeschi, A Boiano… - Journal of …, 2019 - iopscience.iop.org
The Muon g− 2 experiment, E989, is currently taking data at Fermilab with the aim of
reducing the experimental error on the muon anomaly by a factor of four and possibly …

Design and performance of SiPM-based readout of PbF2 crystals for high-rate, precision timing applications

J Kaspar, AT Fienberg, DW Hertzog… - Journal of …, 2017 - iopscience.iop.org
We have developed a custom amplifier board coupled to a large-format 16-channel
Hamamatsu silicon photomultiplier device for use as the light sensor for the electromagnetic …

Characterization and performance of PADME's Cherenkov-based small-angle calorimeter

A Frankenthal, J Alexander, B Buonomo… - Nuclear Instruments and …, 2019 - Elsevier
The PADME experiment, at the Laboratori Nazionali di Frascati (LNF), in Italy, will search for
invisible decays of the hypothetical dark photon via the process e+ e−→ γ A′, where the …

Muon anomalous magnetic moment in the standard model extension

S Aghababaei, M Haghighat, I Motie - Physical Review D, 2017 - APS
We consider the standard model extension to explore the anomalous magnetic dipole
moment of the muon. In the QED part of the theory for the CP and CPT-even Lorentz …

[HTML][HTML] A new approach for limiting the Lorentz violation term (cμν) through analyzing e− e+→ μ− μ+ scattering in a strong magnetic field

MH Sis - Physics Letters B, 2024 - Elsevier
The present study explores a novel approach to establish a new bound on the Lorentz
violation parameter c μ ν in the muon sector. It is achieved by analyzing the scattering cross …

Performance of the Muon g− 2 calorimeter and readout systems measured with test beam data

KS Khaw, M Bartolini, H Binney, R Bjorkquist… - Nuclear Instruments and …, 2019 - Elsevier
A single calorimeter station for the Muon g− 2 experiment at Fermilab includes the following
subsystems: a 54-element array of PbF 2 Cherenkov crystals read out by large-area SiPMs …

The Muon g− 2 experiment at Fermilab

A Keshavarzi - EPJ Web of Conferences, 2019 - epj-conferences.org
The current~ 3.5 σ discrepancy between the experimental measurement and theoretical
prediction of the muon magnetic anomaly, a µ, stands as a potential indication of the …

Measuring the precession frequency in the E989 Muon g-2 Experiment

A Fienberg - 2019 - digital.lib.washington.edu
The E989 Muon $ g-2$ Experiment aims to measure the anomalous magnetic moment of the
muon, $ a_\mu $, to an unprecedented precision of 140 parts per billion (ppb). There …