Artificial pancreas: past, present, future

C Cobelli, E Renard, B Kovatchev - Diabetes, 2011 - Am Diabetes Assoc
The artificial pancreas (AP), known as closed-loop control of blood glucose in diabetes, is a
system combining a glucose sensor, a control algorithm, and an insulin infusion device. AP …

Diabetes: models, signals, and control

C Cobelli, C Dalla Man, G Sparacino… - IEEE reviews in …, 2009 - ieeexplore.ieee.org
The control of diabetes is an interdisciplinary endeavor, which includes a significant
biomedical engineering component, with traditions of success beginning in the early 1960s …

The UVA/Padova type 1 diabetes simulator goes from single meal to single day

R Visentin, E Campos-Náñez… - Journal of diabetes …, 2018 - journals.sagepub.com
Background: A new version of the UVA/Padova Type 1 Diabetes (T1D) Simulator is
presented which provides a more realistic testing scenario. The upgrades to the previous …

Fully integrated artificial pancreas in type 1 diabetes: modular closed-loop glucose control maintains near normoglycemia

M Breton, A Farret, D Bruttomesso, S Anderson… - Diabetes, 2012 - Am Diabetes Assoc
Integrated closed-loop control (CLC), combining continuous glucose monitoring (CGM) with
insulin pump (continuous subcutaneous insulin infusion [CSII]), known as artificial pancreas …

Modular closed-loop control of diabetes

SD Patek, L Magni, E Dassau… - IEEE Transactions …, 2012 - ieeexplore.ieee.org
Modularity plays a key role in many engineering systems, allowing for plug-and-play
integration of components, enhancing flexibility and adaptability, and facilitating …

“Turn it off!”: diabetes device alarm fatigue considerations for the present and the future

JP Shivers, L Mackowiak, H Anhalt… - Journal of diabetes …, 2013 - journals.sagepub.com
Safe and widespread use of diabetes technology is constrained by alarm fatigue: When
someone receives so many alarms that he or she becomes less likely to respond …

Control-relevant models for glucose control using a priori patient characteristics

K Van Heusden, E Dassau, HC Zisser… - IEEE transactions on …, 2011 - ieeexplore.ieee.org
One of the difficulties in the development of a reliable artificial pancreas for people with type
1 diabetes mellitus (T1DM) is the lack of accurate models of an individual's response to …

Toward a run-to-run adaptive artificial pancreas: In silico results

C Toffanin, R Visentin, M Messori… - IEEE Transactions …, 2017 - ieeexplore.ieee.org
Objective: Contemporary and future outpatient long-term artificial pancreas (AP) studies
need to cope with the well-known large intra-and interday glucose variability occurring in …

The use of reinforcement learning algorithms to meet the challenges of an artificial pancreas

MK Bothe, L Dickens, K Reichel… - Expert review of …, 2013 - Taylor & Francis
Blood glucose control, for example, in diabetes mellitus or severe illness, requires strict
adherence to a protocol of food, insulin administration and exercise personalized to each …

Closed-loop control of circulating drug levels in live animals

PL Mage, BS Ferguson, D Maliniak… - Nature Biomedical …, 2017 - nature.com
Current methods of drug dosing rely on physical parameters (such as sex, age and weight)
that do not account for genetic and physiological differences among individual patients …