Comparison of outcomes between single long stent and overlapping stents: A meta-analysis of the literature

F Şaylık, T Çınar, M Selçuk, V Çiçek, MI Hayıroğlu… - Herz, 2023 - Springer
Objectives There is no consensus on whether to treat diffuse coronary artery lesions with a
single long stent (SLS) or by overlapping two or more stents (OLS). The goal of this review …

Mechanical fingerprint of senescence in endothelial cells

N Chala, S Moimas, C Giampietro, X Zhang… - Nano Letters, 2021 - ACS Publications
Endothelial senescence entails alterations of the healthy cell phenotype, which accumulate
over time and contribute to cardiovascular disease. Mechanical aspects regulating cell …

Superficial femoral artery stenting: impact of stent design and overlapping on the local hemodynamics

M Colombo, A Corti, D Gallo, A Colombo… - Computers in Biology …, 2022 - Elsevier
Abstract Background Superficial femoral arteries (SFAs) treated with self-expanding stents
are widely affected by in-stent restenosis (ISR), especially in case of long lesions and …

Structural and hemodynamic analyses of different stent structures in curved and stenotic coronary artery

L Wei, HL Leo, Q Chen, Z Li - Frontiers in bioengineering and …, 2019 - frontiersin.org
Coronary artery stenting is commonly used for the treatment of coronary stenosis, and
different stent structures indeed have various impacts on the stress distribution within the …

Histopathologic and physiologic effect of overlapping vs single coronary stents: impact of stent evolution

A Sakamoto, S Torii, H Jinnouchi… - Expert Review of …, 2018 - Taylor & Francis
Introduction: Bare metal stents (BMS) and drug eluting stents (DES) have been deployed in
single and overlap configurations, the latter mostly to cover long-lesions. Both type of stents …

Computational fluid dynamics analysis of balloon-expandable coronary stents: influence of stent and vessel deformation

DM Martin, EA Murphy, FJ Boyle - Medical engineering & physics, 2014 - Elsevier
In many computational fluid dynamics (CFD) studies of stented vessel haemodynamics, the
geometry of the stented vessel is described using non-deformed (NDF) geometrical models …

Numerical simulation of magnetic nanoparticle-based drug delivery in presence of atherosclerotic plaques and under the effects of magnetic field

M Varmazyar, MR Habibi, M Amini, AH Pordanjani… - Powder Technology, 2020 - Elsevier
The effect of stenosis on magnetonanoparticles (MNPs) distribution within the lumen is
presented in pulsatile blood flow in the presence of a non-uniform magnetic field. The effects …

Acute stent-induced endothelial denudation: biomechanical predictors of vascular injury

C Conway, FR Nezami, C Rogers… - Frontiers in …, 2021 - frontiersin.org
Recent concern for local drug delivery and withdrawal of the first Food and Drug
Administration-approved bioresorbable scaffold emphasizes the need to optimize the …

Drug deposition in coronary arteries with overlapping drug-eluting stents

F Rikhtegar, ER Edelman, U Olgac… - Journal of Controlled …, 2016 - Elsevier
Drug-eluting stents are accepted as mainstream endovascular therapy, yet concerns for their
safety may be under-appreciated. While failure from restenosis has dropped to below 5 …

Optimized computer-aided segmentation and three-dimensional reconstruction using intracoronary optical coherence tomography

L Athanasiou, FR Nezami, MZ Galon… - IEEE journal of …, 2017 - ieeexplore.ieee.org
We present a novel and time-efficient method for intracoronary lumen detection, which
produces three-dimensional (3-D) coronary arteries using optical coherence tomographic …