[HTML][HTML] Bi-Level damped double-tuned harmonic passive filters design: Multi-criteria decision-making analysis

AM Zobaa, SHEA Aleem, HKM Youssef - Ain Shams Engineering Journal, 2023 - Elsevier
Harmonic distortion levels in current power systems have increased due to technical
advancements in industrial and renewable energy applications. So far, passive power filters …

Optimal double-tuned filter efficiency analysis

R Klempka - IEEE Transactions on Power Delivery, 2020 - ieeexplore.ieee.org
The rapid development of technology allows designing better and better filter systems.
Active filters are more and more often used. They also have their drawbacks, including their …

DC-side harmonic analysis and DC filter design in hybrid HVDC transmission systems

J Liao, N Zhou, Q Wang - International Journal of Electrical Power & Energy …, 2019 - Elsevier
Hybrid high-voltage direct current (HVDC) transmission is a new transmission structure that
uses line commutated converter (LCC) at the rectifier side and voltage source converter …

Integrating battery into MMC submodule using passive technique

SB Wersland, AB Acharya… - 2017 IEEE 18th Workshop …, 2017 - ieeexplore.ieee.org
The modular structure and the many other advantages of the Modular Multilevel Converter
makes it an attractive converter for Battery Energy Storage Systems, allowing the battery …

Study on steady-and transient-state characteristics of a new HVDC transmission system based on an inductive filtering method

Y Li, Z Zhang, C Rehtanz, L Luo… - IEEE Transactions on …, 2010 - ieeexplore.ieee.org
Different from the main circuit topology of the traditional current source converter (CSC)-
based HVdc transmission system, this paper proposes a new CSC-HVdc transmission …

Resonance frequency‐based protection scheme for ultra‐high‐voltage direct‐current transmission lines

Y Yang, N Tai, C Fan, L Yang… - IET Generation …, 2018 - Wiley Online Library
Direct‐current (DC) line faults are a major issue in ultra‐high‐voltage direct‐current systems
due to the complex and wicked environment. Thus, reliably detecting and isolating the DC …

[HTML][HTML] Analytical optimization of the filtration efficiency of a group of single branch filters

R Klempka - Electric Power Systems Research, 2022 - Elsevier
This article presents an analysis of a group of single branch filters. The analytical
maximization of the harmonic reduction is examined based on the location of the maximum …

[PDF][PDF] Overview of double tuned harmonic filters in improving power quality under nonlinear load conditions

A Rangampet - International Journal of Grid and Distributed …, 2017 - academia.edu
Improving power quality play a vital role in distribution systems since, these are majorly
connected to nonlinear loads. Nonlinear loads generate harmonics, which in turn disturb the …

[HTML][HTML] A system-level harmonic mitigation method for HVDC systems–A practical case study

Y Wang, K Song, J Zhao, X Xiao, Y Wang - International Journal of …, 2024 - Elsevier
In recent years, non-characteristic harmonic resonance was observed in several high-
voltage direct current (HVDC) systems in China. Intuitively, additional filters can be installed …

Novel Double-Damped Tuned AC Filters in HVDC Systems

RS Mehmood, A Hussain, U Ali… - Computers, Materials and …, 2023 - Elsevier
This paper presents a performance analysis of novel double-damped tuned alternating
current (AC) filters in high voltage direct current (HVDC) systems. The proposed double …