[HTML][HTML] A FE study on the effect of interference fit and coefficient of friction on the micromotions and interface gaps of a cementless PEEK femoral component

CE Post, T Bitter, A Briscoe, N Verdonschot… - Journal of …, 2022 - Elsevier
The use of a more compliant material, such as polyetheretherketone (PEEK), for a
cementless femoral component is a potential solution to prevent aseptic loosening caused …

The effects of cyclic loading and motion on the implant–cement interface and cement mantle of PEEK and cobalt–chromium femoral total knee arthroplasty implants: a …

L De Ruiter, RM Cowie, LM Jennings, A Briscoe… - Materials, 2020 - mdpi.com
This study investigated the fixation of a cemented PEEK femoral TKA component. PEEK and
CoCr implants were subjected to a walking gait cycle for 10 million cycles (MC), 100,000 …

[HTML][HTML] The effect of different interference fits on the primary fixation of a cementless femoral component during experimental testing

E Sánchez, C Schilling, TM Grupp, A Giurea… - journal of the …, 2021 - Elsevier
Cementless femoral total knee arthroplasty (TKA) components use a press-fit (referred to as
interference fit) to achieve initial fixation. A higher interference fit could lead to a superior …

Computational biomechanics of knee joint arthroplasty: a review

KT KANG, YG KOH, JA LEE, HJ CHUN - Mechanical Engineering …, 2020 - jstage.jst.go.jp
Computational models have been widely used for more than four decades to evaluate the
mechanical behavior of knee joint arthroplasty. Validated computational models provide a …

Experimental and computational analysis of micromotions of an uncemented femoral knee implant using elastic and plastic bone material models

S Berahmani, D Janssen, N Verdonschot - Journal of biomechanics, 2017 - Elsevier
It is essential to calculate micromotions at the bone-implant interface of an uncemented
femoral total knee replacement (TKR) using a reliable computational model. In the current …

The influence of body weight index on initial stability of uncemented femoral knee protheses: A finite element study

Q Wan, A Zhang, Y Liu, H Chen, J Zhang, H Xue… - Heliyon, 2023 - cell.com
Background and objective Obesity is one of the risk factors for osteoarthritis. The end-stage
treatment for osteoarthritis is total knee arthroplasty (TKA). However, it remains controversial …

Evaluation of interference fit and bone damage of an uncemented femoral knee implant

S Berahmani, M Hendriks, JJA de Jong… - Clinical …, 2018 - Elsevier
Background During implantation of an uncemented femoral knee implant, press-fit
interference fit provides the primary stability. It is assumed that during implantation a …

Stem to prevent periprosthetic fracture after notching in total knee arthroplasty

Q Wan, A Zhang, Y Liu, H Chen, X Zhao… - International Journal …, 2024 - Wiley Online Library
Improper osteotomy during total knee arthroplasty (TKA) can lead to anterior femoral
notching, which increases the risk of periprosthetic fractures due to stress concentration …

[HTML][HTML] Appropriate sagittal positioning of femoral components in total knee arthroplasty to prevent fracture and loosening: a finite element study

Q Wan, Q Han, Y Liu, H Chen, A Zhang… - Bone & Joint …, 2024 - pmc.ncbi.nlm.nih.gov
Aims This study aimed to investigate the optimal sagittal positioning of the uncemented
femoral component in total knee arthroplasty to minimize the risk of aseptic loosening and …

[HTML][HTML] The effect of bone relaxation on the simulated pull-off force of a cementless femoral knee implant

T Gersie, T Bitter, R Freeman, N Verdonschot… - Journal of …, 2025 - Elsevier
Aseptic loosening is the primary cause of revision in cementless total knee arthroplasty
(TKA), emphasizing the importance of strong initial stability for long-term implant success …