Numerical study on behavior of bolted shear connector used in composite cold-formed steel beams

M Hosseinpour, M Zeynalian, M Daei, A Ataei - Thin-Walled Structures, 2022 - Elsevier
The use of concrete slab in cold-formed steel (CFS) beams can not only increase the
ultimate resistance, but also can prevent their lateral buckling. Since the formation of …

Neural networks-based formulation for predicting ultimate strength of bolted shear connectors in composite cold-formed steel beams

M Hosseinpour, M Daei, M Zeynalian, A Ataei - Engineering Applications of …, 2023 - Elsevier
In recent years, the use of artificial intelligence-based methods in engineering problems has
been expanded. In the current study, the method of artificial neural networks (ANN) has …

Performance of Novel U-Connector in CFS Truss-to-Column Bolted Connection under Axial Force

L Lukačević, P Krolo, A Bakran, I Palijan - Buildings, 2023 - mdpi.com
This paper presents an experimental and numerical investigation of the tensile and
compressive behaviour of a novel U-connector in the cold-formed steel (CFS) truss-to …

Experimental analysis of the cold-formed steel beam-to-column connection using the welded clip-angle

N Mallepogu, M Madhavan - Thin-Walled Structures, 2022 - Elsevier
An experimental investigation on the fillet welded clip-angle connection between the cold-
formed steel (CFS) beam and column was conducted under four-point bending. The …

Numerical study on the stiffness and ultimate strength of cold-formed steel C-shaped connectors under pull-out failure

M Obeydi, IM Baltork, M Zeynalian - Australian Journal of Structural …, 2023 - Taylor & Francis
In this paper, cold-formed steel C-shaped connectors, as one of the most commonly used
components in steel wall/framing systems, were investigated under the pull-out failure …

[HTML][HTML] An experimental study of cold-formed steel connections with screwed clip angle under tension and shear loads

RP Bohara, T Le, HT Thai, T Ngo - Structures, 2024 - Elsevier
This paper aims to investigate the performance of typical cold-formed steel (CFS) beam-to-
beam connections between floor bearers and floor joists through a series of full-scale …

[HTML][HTML] Numerical modelling and design of cold-formed steel battens subject to pull-out failures under bushfire conditions

G Athmarajah, M Mahendran, A Ariyanayagam - Engineering Structures, 2024 - Elsevier
Thin and high strength cold-formed steel (CFS) battens and claddings serve as non-
combustible elements in roof and wall cladding systems, aligning with the recommendations …

[HTML][HTML] Numerical studies of pull-through failures in cold-formed steel battens at sub-zero temperatures

G Athmarajah, M Mahendran - Journal of Constructional Steel Research, 2024 - Elsevier
Cold-formed steel (CFS) roof and wall cladding systems comprising thin, high strength steel
battens and claddings are popularly used in the building industry worldwide. These cladding …

[HTML][HTML] Pull-out capacities of screw connections in thin steel battens exposed to bushfire conditions

G Athmarajah, M Mahendran, A Ariyanayagam - Thin-Walled Structures, 2024 - Elsevier
External building envelopes made of cold-formed steel (CFS) claddings are commonly used
in bushfire prone areas due to their non-combustible properties. However, their designs …

[HTML][HTML] Pull-out failure capacities of cold-formed steel batten screw connections at sub-zero temperatures

G Athmarajah, M Mahendran - Journal of Constructional Steel Research, 2024 - Elsevier
Cold-formed steel (CFS) roof and wall cladding systems are used worldwide, and are
constructed using high-strength, thin steel battens and claddings. In North American …