Single-ended protection method for hybrid HVDC transmission line based on transient voltage characteristic frequency band

H Shu, S Wang, S Lei - … and Control of Modern Power Systems, 2023 - ieeexplore.ieee.org
Hybrid high-voltage direct current (HVDC) transmission has the characteristic of long
transmission distance, complex corridor environment, and rapid fault evolution of direct …

A data set accuracy weighted random forest algorithm for IoT fault detection based on edge computing and blockchain

W Zhang, J Wang, G Han, S Huang… - IEEE Internet of …, 2020 - ieeexplore.ieee.org
The continuously increasing number of connected smart devices has led to the emergence
of a crucial fault detection challenge to the Internet of Things (IoT). In this study, we aim to …

Multiscale Gaussian process regression-based generalized likelihood ratio test for fault detection in water distribution networks

R Fazai, M Mansouri, K Abodayeh, V Puig… - … Applications of Artificial …, 2019 - Elsevier
This paper proposes a new leak/contaminant detection approach that aims to enhance the
monitoring of water distribution network (WDN). The developed method relies on using …

A method for fault section identification in High voltage direct current transmission lines using one End measurements

S Agarwal, A Swetapadma, C Panigrahi… - Electric Power Systems …, 2019 - Elsevier
To identify the section of fault in line commutated converter based high voltage direct current
transmission lines, a new technique has been proposed in this work. The proposed …

Fault ride-through capability enhancement of voltage source converter-high voltage direct current systems with bridge type fault current limiters

M Shafiul Alam, MAY Abido - Energies, 2017 - mdpi.com
This paper proposes the use of bridge type fault current limiters (BFCLs) as a potential
solution to reduce the impact of fault disturbance on voltage source converter-based high …

Assessment of groundwater potential using neural network: a case study

S Samantaray, A Sahoo, DK Ghose - … of 3rd ICICC 2019, Bangalore 3, 2020 - Springer
To properly utilize and manage exploitation of groundwater, application of recent methods is
very much crucial to prepare an organized arrangement for protecting this valuable but …

Fault detection and classification for voltage source converter-high voltage systems by using different swarm optimization algorithms-based neural network

RS Jawad, H Abid - Engineered Science, 2023 - espublisher.com
In high voltage direct current (HVDC) systems, detecting faults has gained a lot of
importance. Due to bulk power transmitted through the system where any faults not detected …

Fault analysis method of integrated high voltage direct current transmission lines for onshore wind farm

S Agarwal, A Swetapadma, C Panigrahi… - Journal of Modern …, 2019 - ieeexplore.ieee.org
Voltage source converter (VSC) based high voltage direct current (HVDC) transmission is
most suited for the wind farm as it allows flexibility for reactive power control in multi-terminal …

A high-speed protection strategy for bipolar CSC-Based HVDC transmission system

SJ Ankar, A Yadav - Electric Power Components and Systems, 2021 - Taylor & Francis
This paper introduces a novel approach to high-speed fault protection strategy for bipolar
Current Source Converter (CSC) based high voltage DC transmission line. The Bagged …

Improved distance relaying for double-circuit lines using adaptive neuro-fuzzy inference system

TA Kawady, GM Sowilam, R Shalwala - Arabian Journal for Science and …, 2020 - Springer
Utilizing double-circuit lines may represent a challenge for distance relaying functions owing
to the significant impacts of the mutual coupling among the adjacent conductors. This paper …