Power module for low voltage DC hybrid circuit breaker

K Askan, M Bartonek… - 2019 IEEE Third …, 2019 - ieeexplore.ieee.org
This paper presents design and development of a power module used in a low voltage DC
hybrid circuit breaker (HCB). The novel power module is rated for 125 A/380 V and can …

Electrical lifespan prediction of HVDC relay based on the accumulated arc erosion mass

X Cui, X Zhou, G Zhai, Z Fang… - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
Electrical lifespan prediction is one of the key problems for the designers of switching
apparatus. It is of great necessity to develop empirical correlations between the design …

Influence of arc discharge on contact erosion and contact resistance in a hybrid DC switch

C Ou, R Nakayama, S Zen, N Takeuchi… - 2018 IEEE Holm …, 2018 - ieeexplore.ieee.org
Contact erosion due to an arc discharge is a critical problem particularly for a DC switch or a
DC circuit breaker. Longer duration arc causes higher degradation of their reliability and …

Influence of a short-duration arc on the erosion and dielectric strength of narrow air-gap contacts in a hybrid DC switch

C Ou, R Nakayama, S Zen… - IEEE Transactions on …, 2019 - ieeexplore.ieee.org
Contact erosion and dielectric strength reduction due to arc discharge are critical problems,
particularly for dc switches and circuit breakers. Long-duration arcs not only cause serious …

Research on Surge Voltage Withstand of Medium Voltage Vacuum Reed Relay

P Oramus, K Kóska, J Kozak… - 2018 14th Selected …, 2018 - ieeexplore.ieee.org
This paper presents results of experiments carried out in order to determine surge voltage
withstand of vacuum reed relay which is not given in the catalogue notes. Three MV vacuum …

Pre-arcing time prediction in a making test for a 420 kV 63 kA high-speed earthing switch

MC Kang, KH Kim, YT Yoon - Energies, 2017 - mdpi.com
A high-speed earthing switch (HSES) of a gas-insulated switchgear (GIS) performs a
secondary role in protecting the power system in the event of an accident. After being …

Application of bidirectional transient voltage suppressor for electric arc suppression in LV switches-simulation and laboratory case study

P Oramus, T Chmielewski, T Kuczek… - 2017 Progress in …, 2017 - ieeexplore.ieee.org
This paper presents the analysis of bidirectional Transient Voltage Suppressor (TVS)
application for limitation of the electric arc energy in a low voltage circuit. The study employs …

Inrush current impact limitation in smart building applications.

M Stosur, K Sowa, P Oramus… - Przeglad …, 2022 - search.ebscohost.com
This paper presents a hybrid switches based on semiconductors and mechanical switches.
Devices are dedicated to limitation of adverse effect of capacitive type loads start-up …

Investigation into limitation of electric arc energy in LV switch installed in AC circuit through application of time‐controlled contact separation

P Oramus, M Florkowski - International Transactions on …, 2017 - Wiley Online Library
This paper presents results from performed research on a mitigation of an electric arc in a LV
switch through an application of a time‐controlled separation of contacts of the tested switch …

Pre-arc 시간예측기법을고려한고속접지개폐기전극형상설계

강민철 - 2018 - s-space.snu.ac.kr
2 차 아크 전류는 송전선로에서 발생되는 1 차 사고 전류 (혹은 1 차 아크 전류) 차단 이후에
추가적으로 발생되는 사고 전류를 의미한다. 2 차 아크 전류는 주로 1 상 지락 사고 시 …