Investigation into islanding detection with capacitor insertion-based method

D Bejmert, TS Sidhu - IEEE Transactions on Power Delivery, 2014 - ieeexplore.ieee.org
When islanding conditions arise, local distribution companies usually require the
disconnection of all distributed generations from the isolated grid. For this purpose, mainly …

Techniques for the diagnosis of oscillatory transients resulting from capacitor bank switching in medium voltage distribution systems

ABG Hoffmann, CH Beuter, ALS Pessoa… - International Journal of …, 2021 - Elsevier
The oscillatory transient has well-dened characteristics such as short duration, considerable
variations in the voltage's amplitude, and frequency, which can be manifested in any part of …

[PDF][PDF] A novel passive method for islanding detection in microgrids

F Namdari, M Parvizi, E Rokrok - Iranian Journal of Electrical and …, 2016 - academia.edu
Integration of Distributed Generations (DGs) in power grids is expected to play an essential
role in the infrastructure and market of electrical power systems. Microgrids are small energy …

[PDF][PDF] Reactive power based anti-islanding scheme for synchronous distributed generators

MBR Noroozian - … Journal on “Technical and Physical Problems …, 2012 - researchgate.net
Identification of intentional and unintentional islanding situation of the dispersed generators
is one of the important protection concerns in both traditional and smart grids. Regarding the …

An investigative study of the application of fundamental operations of mathematical morphology in the diagnosis of oscillatory transients

ABG Hoffmann, CH Beuter… - 2022 20th International …, 2022 - ieeexplore.ieee.org
The Oscillatory Transient (OT) has defined characteristics such as a small duration,
considerable variations in the voltage and frequency amplitude and can manifest itself in …

[PDF][PDF] Feasible method for optimal capacitor placement in a distributed system by using game theory

MH Sadeghi, A Darabi, H Yassami, M Owladi… - International Journal on …, 2011 - iotpe.com
The utilities are interested on economic and optimal projects which improve their services to
customers. These projects should increase the utilities' profit as well. Reactive power …

[PDF][PDF] 36KV-630A SINGLE SHAFT 3-PHASE MAGNETIC ARC INTERRUPTER LBS DESIGN FOR SMART GRID APPLICATIONS

EC Altinok, EGSUT Unver… - … Journal on “Technical …, 2021 - researchgate.net
A Load Break Switch (LBS) is the switching device that used to switching of the current in the
electric power systems. Among the medium voltage products in the world market, 36 kV LBS …