A model of the upper extremity for simulating musculoskeletal surgery and analyzing neuromuscular control

KRS Holzbaur, WM Murray, SL Delp - Annals of biomedical engineering, 2005 - Springer
Biomechanical models of the musculoskeletal system are frequently used to study
neuromuscular control and simulate surgical procedures. To be broadly applicable, a model …

Electrode size and placement for surface emg bipolar detection from the brachioradialis muscle: A scoping review

A Merlo, MC Bo, I Campanini - Sensors, 2021 - mdpi.com
The brachioradialis muscle (BRD) is one of the main elbow flexors and is often assessed by
surface electromyography (sEMG) in physiology, clinical, sports, ergonomics, and …

[图书][B] Ergonomics in design: Methods and techniques

MM Soares, F Rebelo - 2016 - api.taylorfrancis.com
Currently people deal with various entities (such as hardware, software, buildings, spaces,
communities and other people), to meet specific goals while going about their everyday …

Electromyographic activity and strength during maximum isometric pronation and supination efforts in healthy adults

KD Gordon, RD Pardo, JA Johnson… - Journal of …, 2004 - Wiley Online Library
There exists a lack of quantitative data in the literature related to the torque produced during
axial forearm rotation and the electromyographic (EMG) activity of the muscles involved …

Quantification of pronator quadratus contribution to isometric pronation torque of the forearm

MO McConkey, TD Schwab, A Travlos… - The Journal of hand …, 2009 - Elsevier
PURPOSE: The contribution of the pronator quadratus (PQ) muscle in generation of
pronation torque has not been determined. The purpose of this study was to investigate …

The pronator quadratus muscle after plating of distal radius fractures: is the muscle still working?

M Armangil, U Bezirgan, K Başarır, G Bilen… - European Journal of …, 2014 - Springer
The purpose of this study is to define the function of the pronator quadratus muscle after
plating of a distal radius fracture using anterior (volar) approach. Fourteen cases with volar …

[HTML][HTML] Neurofeedback of scalp bi-hemispheric EEG sensorimotor rhythm guides hemispheric activation of sensorimotor cortex in the targeted hemisphere

M Hayashi, N Mizuguchi, S Tsuchimoto, J Ushiba - NeuroImage, 2020 - Elsevier
Oscillatory electroencephalographic (EEG) activity is associated with the excitability of
cortical regions. Visual feedback of EEG-oscillations may promote sensorimotor cortical …

Nerve conduction studies of upper extremities in tennis players

T Colak, B Bamac, A Özbek, F Budak… - British journal of sports …, 2004 - bjsm.bmj.com
Objectives: The influence of regular and intense practice of an asymmetric sport such as
tennis on nerves in the elbow region was examined. Methods: The study included 21 male …

A human forearm and wrist motion assist exoskeleton robot with EMG-based fuzzy-neuro control

R Gopura, K Kiguchi - 2008 2nd IEEE RAS & EMBS …, 2008 - ieeexplore.ieee.org
In this paper, an EMG-based fuzzy-neuro control method is proposed for a three degree of
freedom (3 DOF) human forearm and wrist motion assist exoskeleton robot (W-EXOS). The …

A structural numerical model for the optimization of double pelvic osteotomy in the early treatment of canine hip dysplasia

EM Zanetti, M Terzini, L Mossa… - Veterinary and …, 2017 - thieme-connect.com
Background: Double pelvic osteotomy (DPO) planning is usually performed by hip palpation,
and on radiographic images which give a poor representation of the complex three …