[图书][B] Power system stability and control

LL Grigsby - 2007 - taylorfrancis.com
Part of the second edition of The Electric Power Engineering Handbook, Power System
Stability and Control offers conveniently focused and detailed information covering all …

气体绝缘开关设备中特快速瞬态过电压研究的新进展

陈维江, 颜湘莲, 王绍武, 王承玉, 李志兵… - 中国电机工程 …, 2011 - epjournal.csee.org.cn
气体绝缘开关设备(gas insulated switchgear, GIS) 中的隔离开关操作空载短母线会产生陡波前,
高幅值的特快速瞬态过电压(very fast transient overvoltage, VFTO), 瞬态壳体电位和电磁干扰 …

[图书][B] The electric power engineering handbook-five volume set

LL Grigsby - 2018 - taylorfrancis.com
The Electric Power Engineering Handbook, Third Edition updates coverage of recent
developments and rapid technological growth in crucial aspects of power systems, including …

特高压气体绝缘开关设备中特快速瞬态过电压特性的试验研究

陈维江, 李志兵, 孙岗, 戴敏, 刘卫东… - 中国电机工程 …, 2011 - epjournal.csee.org.cn
陈维江, 李志兵, 孙岗, 戴敏, 刘卫东, 李成榕, 王磊, 王浩, 陈国强, 姚涛, 王森, 卢江平, 吴军辉,
张希捷, 李文艺, 李心一. 特高压气体绝缘开关设备中特快速瞬态过电压特性的试验研究[J] …

宽频电压感知方法及其数据应用

杨庆, 董富宁, 罗曼丹, 孙健, 崔浩楠, 揭青松 - 高电压技术, 2021 - epjournal.csee.org.cn
宽频电压的传感与量测能够为电力系统电能计量, 智能控制以及继电保护提供重要信息,
在电网过电压在线监测, 故障预警, 故障定位与防护以及设备智能化等领域具有重要地位 …

Experimental research on very-fast transient overvoltage in 1100-kV gas-insulated switchgear

Y Shu, W Chen, Z Li, M Dai, C Li… - IEEE Transactions on …, 2012 - ieeexplore.ieee.org
Very-fast transient overvoltage (VFTO) generated during switching of the disconnector in gas-
insulated switchgear (GIS) may threaten the safety operation of electrical equipment. As the …

Analysis of VFTO during the failure of a 550-kV gas-insulated substation

DC Moreira, MVA Nunes, DDC Moreira… - Electric Power Systems …, 2020 - Elsevier
This paper presents an analysis of a very fast transient overvoltage (VFTO) experienced by a
550-kV gas-insulated substation (GIS) that caused the failure of a disconnector switch (DS) …

Experimental research on suppressing VFTO in GIS by magnetic rings

Y Guan, G Yue, W Chen, Z Li… - IEEE Transactions on …, 2013 - ieeexplore.ieee.org
Very-fast transient overvoltage (VFTO) is a serious threat to the insulation of extra-high
voltage and ultra-high voltage power-system equipment and should be suppressed. A …

Time and frequency characteristics of very fast transient overvoltage in ultra high voltage substation

GM Ma, CR Li, X Li, HY Zhou, WJ Chen… - … on Dielectrics and …, 2017 - ieeexplore.ieee.org
Most work about the measurement of very fast transient overvoltage (VFTO) was carried out
in the laboratory and test base. Because of the different GIS arrangement and power …

[引用][C] 1000kV GIS 变电所VFTO 特性研究

谷定燮, 修木洪, 戴敏, 周沛洪 - 高电压技术, 2007