Dose calculations for external photon beams in radiotherapy

A Ahnesjö, MM Aspradakis - Physics in Medicine & Biology, 1999 - iopscience.iop.org
Dose calculation methods for photon beams are reviewed in the context of radiation therapy
treatment planning. Following introductory summaries on photon beam characteristics and …

A literature review of electronic portal imaging for radiotherapy dosimetry

W Van Elmpt, L McDermott, S Nijsten… - Radiotherapy and …, 2008 - Elsevier
Electronic portal imaging devices (EPIDs) have been the preferred tools for verification of
patient positioning for radiotherapy in recent decades. Since EPID images contain dose …

Significant reductions in heart and lung doses using deep inspiration breath hold with active breathing control and intensity-modulated radiation therapy for patients …

VM Remouchamps, FA Vicini, MB Sharpe… - International Journal of …, 2003 - Elsevier
Purpose: To evaluate the heart and lung sparing effects of moderate deep inspiration breath
hold (mDIBH) achieved using an active breathing control (ABC) device, compared with free …

Comparison of dose calculation algorithms for treatment planning in external photon beam therapy for clinical situations

T Knöös, E Wieslander, L Cozzi, C Brink… - Physics in Medicine …, 2006 - iopscience.iop.org
A study of the performance of five commercial radiotherapy treatment planning systems
(TPSs) for common treatment sites regarding their ability to model heterogeneities and …

Clinical use of electronic portal imaging: report of AAPM Radiation Therapy Committee Task Group 58

MG Herman, JM Balter, DA Jaffray, KP McGee… - Medical …, 2001 - Wiley Online Library
AAPM Task Group 58 was created to provide materials to help the medical physicist and
colleagues succeed in the clinical implementation of electronic portal imaging devices …

The use of an aSi-based EPID for routine absolute dosimetric pre-treatment verification of dynamic IMRT fields

A Van Esch, T Depuydt, DP Huyskens - Radiotherapy and oncology, 2004 - Elsevier
BACKGROUND AND PURPOSE: In parallel with the increased use of intensity modulated
radiation treatment (IMRT) fields in radiation therapy, flat panel amorphous silicon (aSi) …

History of tomotherapy

TR Mackie - Physics in Medicine & Biology, 2006 - iopscience.iop.org
Tomotherapy is the delivery of intensity modulated radiation therapy using rotational delivery
of a fan beam in the manner of a CT scanner. In helical tomotherapy the couch and gantry …

Intensity modulation to improve dose uniformity with tangential breast radiotherapy: initial clinical experience

LL Kestin, MB Sharpe, RC Frazier, FA Vicini… - International Journal of …, 2000 - Elsevier
Purpose: We present a new technique to improve dose uniformity and potentially reduce
acute toxicity with tangential whole-breast radiotherapy (RT) using intensity-modulated …

On the dosimetric behaviour of photon dose calculation algorithms in the presence of simple geometric heterogeneities: comparison with Monte Carlo calculations

A Fogliata, E Vanetti, D Albers, C Brink… - Physics in Medicine …, 2007 - iopscience.iop.org
A comparative study was performed to reveal differences and relative figures of merit of
seven different calculation algorithms for photon beams when applied to inhomogeneous …

Megavoltage CT on a tomotherapy system

KJ Ruchala, GH Olivera, EA Schloesser… - Physics in Medicine & …, 1999 - iopscience.iop.org
A megavoltage computed tomography (MVCT) system was developed on the University of
Wisconsin tomotherapy benchtop. This system can operate either axially or helically, and …