JENDL/DEU-2020: deuteron nuclear data library for design studies of accelerator-based neutron sources

S Nakayama, O Iwamoto, Y Watanabe… - journal of nuclear …, 2021 - Taylor & Francis
Intensive fast neutron sources using deuteron accelerators have been proposed for various
applications. To contribute to the design study of such neutron sources, a deuteron nuclear …

First beams at neutrons for science

X Ledoux, JC Foy, JE Ducret, AM Frelin… - The European Physical …, 2021 - Springer
The neutrons for science facility (NFS), the first operational experimental area of the new
GANIL/SPIRAL-2 facility, received its first beams in December 2019. Proton-induced …

Commissioning of a high power linac at GANIL: Beam power ramp-up

AK Orduz, M Di Giacomo, R Ferdinand, B Jacquot… - … Review Accelerators and …, 2022 - APS
SPIRAL2 is a high power linear accelerator part of the GANIL laboratory. This
superconducting (SC) linac can accelerate cw light ions to heavy ions at energies up to 40 …

Scintillation properties of N2 and CF4 and performances of a scintillating ionization chamber

G Lehaut, S Salvador, JM Fontbonne… - Nuclear Instruments and …, 2015 - Elsevier
In this work, we studied the emission yields, decay times and coincidence resolving times
(CRT) of two gases, nitrogen (N 2) and tetrafluoromethane (CF 4), used for particle detection …

The liquid-lithium target at the soreq applied research accelerator facility

M Paul, M Tessler, M Friedman, S Halfon… - The European Physical …, 2022 - Springer
Franz Käppeler and collaborators showed in the 1980's that the 7 Li (p, n) 7 Be reaction can
be used to produce a flux of neutrons having a stellar-like energy distribution, closely similar …

[PDF][PDF] Status of the SPIRAL2 Project

P Dolegieviez, R Ferdinand, X Ledoux… - Proc. 10th Int …, 2019 - accelconf.web.cern.ch
The SPIRAL2 facility at GANIL will use a high-power p, d and heavy-ion superconducting
linac for a wide range of applications including RIB production using both ISOL and in-flight …

Deuteron-induced reactions on up to 60 MeV

E Šimečková, M Avrigeanu, J Mrázek, J Novak… - Physical Review C, 2021 - APS
Background: The deuteron weak binding energy is responsible for high complexity of the
deuteron interaction with nuclei that involves also a variety of reactions initiated by the …

Review of neutron calibration facilities and monitoring techniques: new needs for emerging fields

V Gressier - Radiation protection dosimetry, 2014 - academic.oup.com
Neutron calibration facilities and monitoring techniques have been developed since the
middle of the 20th century to support research and nuclear power energy development. The …

Commissioning and operation of the SPIRAL2 SC linac

A Orduz, PE Bernaudin, M Di Giacomo… - IPAC'23-14th …, 2023 - hal.science
The SPIRAL2 linac is now successfully commissioned; H $^+ $, $^ 4$ He $^{2+} $, D $^+ $
have been accelerated up to nominal parameters and $^{18} $ O $^{6+, 7+} $ and $^{40} …

Fast chopper for single radio-frequency quadrupole bunch selection for neutron time-of-flight capabilities

A Shor, B Kaizer, I Eliyahu, T Hirsh, Y Eisen… - … Review Accelerators and …, 2019 - APS
A fast chopper system has been developed and tested for single bunch selection with the
radio-frequency quadrupole (RFQ) accelerating element of the Soreq Applied Research …