Review of Catheter‐Associated Urinary Tract Infections and In Vitro Urinary Tract Models

YJ Cortese, VE Wagner, M Tierney… - Journal of healthcare …, 2018 - Wiley Online Library
Catheter‐associated urinary tract infections (CAUTIs) are one of the most common
nosocomial infections and can lead to numerous medical complications from the mild …

Evaluating efficacy of antimicrobial and antifouling materials for urinary tract medical devices: Challenges and recommendations

M Ramstedt, IAC Ribeiro, H Bujdakova… - Macromolecular …, 2019 - Wiley Online Library
In Europe, the mean incidence of urinary tract infections in intensive care units is 1.1 per
1000 patient‐days. Of these cases, catheter‐associated urinary tract infections (CAUTI) …

Advancing toward 3D printing of bioresorbable shape memory polymer stents

TR Yeazel, ML Becker - Biomacromolecules, 2020 - ACS Publications
Stents have evolved significantly since their introduction to the medical field in the early
1980s, becoming widely used in percutaneous coronary interventions and following …

Corrosion behavior of Mg wires for ureteral stent in artificial urine solution

D Mei, C Wang, M Nienaber, M Pacheco, A Barros… - Corrosion …, 2021 - Elsevier
Ureteral stents are a relatively new potential application for biodegradable Mg alloys. In this
study, the corrosion behavior of Mg-1Zn wires and pure Mg wires in artificial urine solution …

[HTML][HTML] Influence of ECAP process on mechanical, corrosion and bacterial properties of Zn-2Ag alloy for wound closure devices

GM Claudia, G Ivan, OM Laia, JP Emilio, G Maria-Pau… - Materials & Design, 2023 - Elsevier
Actual polymeric wound closure devices are not optimal for load-bearing applications due to
the low mechanical properties and the risk of inflammation and bacterial infection mainly …

A bilayer swellable drug-eluting ureteric stent: Localized drug delivery to treat urothelial diseases

WS Lim, K Chen, TW Chong, GM Xiong, WR Birch… - Biomaterials, 2018 - Elsevier
A bilayer swellable drug-eluting ureteric stent (BSDEUS) is engineered and implemented,
as a sustained drug delivery platform technology that enhances localized drug delivery to …

A randomized clinical trial evaluating the short-term results of ureteral stent encrustation in urolithiasis patients undergoing ureteroscopy: micro-computed tomography …

T Yoshida, K Takemoto, Y Sakata, T Matsuzaki… - Scientific Reports, 2021 - nature.com
Although many ureteral stents are commercially available, the actuality of encrustation is yet
to be elucidated in humans. This study compared the Tria Ureteral Stent with PercuShield …

Release mechanisms of urinary tract antibiotics when mixed with bioabsorbable polyesters

J Fernandez, IAC Ribeiro, V Martin, OL Martija… - Materials Science and …, 2018 - Elsevier
In depth knowledge of the thermal properties of drugs is particularly important when they are
designed for incorporation into a thermoplastic polymer matrix. In this paper a representative …

Effect of theophylline on stent-related symptoms in patients undergoing Double-J ureteral stent insertion: a randomized controlled trial

A Pakdel, A Mohammadi, H Chivaee… - … Urology and Nephrology, 2024 - Springer
Purpose To investigate the effect of oral theophylline on stent-related syndrome (SRS) after
Double-J insertion. Background Double-J stent is widely using in many urological …

Computational simulation of the flow dynamic field in a porous ureteric stent

X Yang, A Mosayyebi, D Carugo - Medical & Biological Engineering & …, 2022 - Springer
Ureteric stents are employed clinically to manage urinary obstructions or other pathological
conditions. Stents made of porous and biodegradable materials have gained increasing …