60-GHz 64-and 256-elements wafer-scale phased-array transmitters using full-reticle and subreticle stitching techniques

S Zihir, OD Gurbuz, A Kar-Roy… - IEEE Transactions …, 2016 - ieeexplore.ieee.org
This paper presents 60-GHz wafer-scale transmit phased arrays with 64-and 256-elements
spaced λ/2 apart in the x-and y-directions, and occupying an area of 21.4× 22 mm 2 (471 …

Digital image sensor evolution and new frontiers

ER Fossum, N Teranishi… - Annual Review of Vision …, 2024 - annualreviews.org
This article reviews nearly 60 years of solid-state image sensor evolution and identifies
potential new frontiers in the field. From early work in the 1960s, through the development of …

Large area CMOS image sensors

R Turchetta, N Guerrini, I Sedgwick - Journal of Instrumentation, 2011 - iopscience.iop.org
CMOS image sensors, also known as CMOS Active Pixel Sensors (APS) or Monolithic Active
Pixel Sensors (MAPS), are today the dominant imaging devices. They are omnipresent in …

A high frame rate, 16 million pixels, radiation hard CMOS sensor

N Guerrini, R Turchetta, G Van Hoften… - Journal of …, 2011 - iopscience.iop.org
CMOS sensors provide the possibility of designing detectors for a large variety of
applications with all the benefits and flexibility of the widely used CMOS process. In this …

DynAMITe: a wafer scale sensor for biomedical applications

M Esposito, T Anaxagoras, A Fant, K Wells… - Journal of …, 2011 - iopscience.iop.org
In many biomedical imaging applications Flat Panel Imagers (FPIs) are currently the most
common option. However, FPIs possess several key drawbacks such as large pixels, high …

Performance of a novel wafer scale CMOS active pixel sensor for bio-medical imaging

M Esposito, T Anaxagoras… - Physics in Medicine …, 2014 - iopscience.iop.org
Recently CMOS active pixels sensors (APSs) have become a valuable alternative to
amorphous silicon and selenium flat panel imagers (FPIs) in bio-medical imaging …

A synchronous driving approach based on adaptive delay phase-locked loop for stitching CMOS image sensor

Z Guo, N Yu, L Wu - IEICE Electronics Express, 2020 - jstage.jst.go.jp
A synchronous driving approach for stitching CMOS image sensor is proposed. Dual
terminal signal line driver structure must be considered in the design of row control for high …

Research on column FPN and black level calibration in large array CMOS image sensor

G Zhongjie, Y Ningmei… - Chinese Journal of …, 2021 - Wiley Online Library
A technical investigation, research and implementation is presented to correct column fixed
pattern noise and black level in large array Complementary metal oxide semiconductor …

Fast signal transfer in a large-area X-ray CMOS image sensor

MS Kim, DU Kang, DH Lee, H Kim… - Journal of …, 2014 - iopscience.iop.org
For 2-d X-ray imaging, such as mammography and non-destructive test, a sensor should
have a large-area because the sensor for typical X-ray beams cannot use optical lens …

Systematic experimental study on stitching techniques of CMOS image sensors

J Zhu, D Liu, W Zhang, Q Wang, W Li, L Chen… - IEICE Electronics …, 2016 - jstage.jst.go.jp
On the basis of the systematic study of stitching techniques, a large area, 28.3 mm× 38.8
mm, 42 Mega pixels CMOS Imaging Sensor (CIS) had been demonstrated on 12 inch silicon …