Selective pole placement and cancellation for proportional–resonant control design used in voltage source inverter

B Lin, L Peng, X Liu - IEEE Transactions on Power Electronics, 2022 - ieeexplore.ieee.org
The proportional–integral (PI) control is usually applied in synchronous reference frame to
regulate the output voltage of three-phase voltage source inverter (VSI). However, the PI …

Closed-form harmonic compensation using resonant controllers applied to four-leg VSI

E Oggier, GG Oggier, F Botteron… - IEEE Journal of …, 2023 - ieeexplore.ieee.org
Harmonic compensation employing resonant controllers applied to voltage source inverters
(VSIs) generally requires complex techniques or a trial-and-error process to design the …

Digital single voltage loop control of a VSI with LC output filter

IDN de Souza, PM de Almeida, PG Barbosa… - … Energy, Grids and …, 2018 - Elsevier
This paper deals with the output voltage control problem of a three-phase three-wire voltage
source Inverter (VSI) with LC output filter. A novel discrete-time active damping technique is …

[HTML][HTML] A Multi-Resonant based reference feedforward adaptive voltage control for Grid-Forming inverter in island mode to compensate system uncertain and …

R Huang, Z Wu, X Xu, X Quan, M Li, Z Wang… - International Journal of …, 2025 - Elsevier
This paper investigates a novel adaptive voltage control over a three-phase grid-forming
(GFM) inverter. The proposed voltage controller includes two function parts: power control …

Double virtual-impedance loop for inverters with repetitive and droop control in UPS applications

J Astrada, C De Angelo - Electric Power Systems Research, 2022 - Elsevier
A strategy for the implementation of the output impedance in multi-loop inverters with
repetitive control for uninterruptible power supply applications is proposed. The …

Multiple resonant controllers strategy to achieve fault ride‐through and high performance output voltage in UPS applications

RE Carballo, F Botterón, GG Oggier… - IET Power …, 2018 - Wiley Online Library
A control strategy to achieve fault ride‐through capability and to provide high performance of
the output voltage of a single‐phase uninterruptible power supply (UPS) inverter is …

Design and implementation of an optimal switching controller for uninterruptible power supply inverters using adaptive dynamic programming

A Gogani Khiabani, A Heydari - IET Power Electronics, 2019 - Wiley Online Library
In this study, a new approach based on adaptive dynamic programming (ADP) is proposed
to control single‐phase uninterruptible power supply inverters. The control scheme uses a …

Analysis of proportional-resonant damping factors in the parallel operation of UPSs

G Keiel, JV Flores, LFA Pereira - ISA transactions, 2025 - Elsevier
Accurate load-sharing and circulating current mitigation is a particular problem in parallel-
connected inverters without intercommunication. This paper analyzes how using multiple …

An adaptive proportional resonant controller for single phase PV grid connected inverter based on band-pass filter technique

H Khalfalla, S Ethni, M Al-Greer… - 2017 11th IEEE …, 2017 - ieeexplore.ieee.org
This paper presents an adaptive proportional resonant (PR) controller for single phase grid
connected inverter that adapts its control parameters to grid impedance variations. Forth …

Implementation of output impedance in single‐phase inverters with repetitive control and droop control

J Astrada, C De Angelo - IET Power Electronics, 2020 - Wiley Online Library
A strategy for the implementation of the output impedance in single‐phase inverters
connected in parallel with droop control for uninterruptible power supply applications is …