A review on factors that affect surface charge accumulation and charge-induced surface flashover

M Yuan, L Zou, Z Li, L Pang, T Zhao, L Zhang… - …, 2021 - iopscience.iop.org
The surface charge accumulation is very likely to trigger the surface flashover, which limits
the large-scale application of DC GIL/GIS. This article comprehensively reviews the effect of …

High voltage insulation properties of HFO1234ze

M Koch, CM Franck - IEEE Transactions on Dielectrics and …, 2015 - ieeexplore.ieee.org
Recently it was shown that it is possible to predict the breakdown voltages of arbitrary
electrode configurations under standard voltage applications for electron attaching gases …

Positive Streamer Initiation in SF6/CO2 Based on Zener's Field Ionization

MF Abbas, YL He, GY Sun, AB Sun, ET Eldin… - Ieee …, 2023 - ieeexplore.ieee.org
In this study, experiments were performed to measure the inception and breakdown voltages
of SF6/CO2 mixed gases with varying mixing ratios at two different pressures (1 and 2 bar) …

Experimental investigation of streamer radius and length in SF6

M Bujotzek, M Seeger, F Schmidt… - Journal of Physics D …, 2015 - iopscience.iop.org
SF 6 has for decades been widely used in high voltage insulation and switching
applications, eg in gas insulated switchgear. Despite its widespread use some important …

An efficient procedure to identify and quantify new molecules for insulating gas mixtures

CM Franck, DA Dahl, M Rabie… - … to Plasma Physics, 2014 - Wiley Online Library
In this contribution, a new procedure to systematically identify and quantify novel molecular
gases with low global warming potential for application in high voltage insulation as gas …

Hybrid Numerical Simulation of Decomposition of SF6 Under Negative DC Partial Discharge Process

F Zeng, M Zhang, D Yang, J Tang - Plasma Chemistry and Plasma …, 2019 - Springer
To reveal the decomposition mechanism of SF 6 under negative DC partial discharge (PD),
a PD hybrid numerical model of SF 6 was constructed based on fluid dynamics and plasma …

Breakdown fields in synthetic air, CO2, a CO2 / O2 mixture, and CF4 in the pressure range 0.5–10 MPa

M Seeger, P Stoller, A Garyfallos - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
The breakdown electric field strength in synthetic air, CO 2, a mixture of CO 2 and O 2, and
CF 4 was investigated under conditions relevant for high voltage insulation systems …

Application of X-ray inspection for ultra high voltage gas-insulated switchgear

J Wang, W Ding, Y Liu, Z Zheng… - IEEE Transactions on …, 2019 - ieeexplore.ieee.org
Owing to the strong penetration ability of X-rays and the imaging visibility, X-ray inspection
has been gradually applied to power grids. However, various problems occur in the …

Microscopic charge provision at interfaces of gas-insulated (HVDC/HVAC) systems

M Tschentscher, CM Franck - IEEE Transactions on Dielectrics …, 2018 - ieeexplore.ieee.org
Charge generation at the interfaces of gas-insulated switchgear or gas-insulated lines is
mostly studied from a macroscopic point of view. Integral current measurements are a …

Research on effectiveness of lightning impulses with different parameters for detecting protrusion defects in GIS

L Zhang, C He, R Guo, W Yuan… - IEEE Transactions on …, 2020 - ieeexplore.ieee.org
The focus of this paper is on the effectiveness of lightning impulse (LI) with different
parameters for detecting protrusion defects in gas insulated switchgear (GIS). The study …