Microfluidic platform for negative enrichment of circulating tumor cells

BNG Sajay, CP Chang, H Ahmad, P Khuntontong… - Biomedical …, 2014 - Springer
Negative enrichment is the preferred approach for tumor cell isolation as it does not rely on
biomarker expression. However, size-based negative enrichment methods suffer from well …

Integration of semiconductor quantum dots into nano-bio-chip systems for enumeration of CD4+ T cell counts at the point-of-need

JV Jokerst, PN Floriano, N Christodoulides… - Lab on a Chip, 2008 - pubs.rsc.org
Recent humanitarian efforts have led to the widespread release of antiretroviral drugs for the
treatment of the more than 33 million HIV afflicted people living in resource-scarce settings …

Carbon-13 nuclear magnetic resonance analysis of formaldehyde free preservatives

K Das, J Dumais, S Basiaga, GD Krzyzanowski - Acta histochemica, 2013 - Elsevier
Preservation of biomolecules is pivotal in increasingly important molecular diagnostics.
Traditionally, formaldehyde is employed for such biomolecular preservation in spite of its …

Multisite evaluation of point of care CD4 testing in Papua New Guinea

M Malagun, G Nano, C Chevallier, R Opina, G Sawiya… - PLoS …, 2014 - journals.plos.org
Laboratory-based CD4 monitoring of HIV patients presents challenges in resource limited
settings (RLS) including frequent machine breakdown, poor engineering support and limited …

Interlaboratory comparison of the TransFix®/EDTA Vacuum Blood Collection tube with the 5 mL Cyto‐Chex® BCT

D Harrison, R Ward, S Bastow, A Parr… - Cytometry Part B …, 2019 - Wiley Online Library
Background An interlaboratory study was performed to compare the performance of the 3
mL TransFix®/EDTA Vacuum Blood Collection Tube (TVT), with the 5 mL Cyto‐Chex® BCT …

Research needs and challenges in the development of HIV diagnostic and treatment monitoring tests for use in resource-limited settings

B Cheng, A Landay, V Miller - Current Opinion in HIV and AIDS, 2008 - journals.lww.com
Increased availability of antiretroviral therapy in resource-limited settings increases the need
for reliable, less costly and simpler to use HIV diagnostic and treatment monitoring …

Advances in CD4 cell enumeration in resource-poor countries

LL Baum, S Crowe, AL Landay - Current opinion in HIV and AIDS, 2007 - journals.lww.com
The availability of antiretroviral medications increases the need for CD4 cell assays to
monitor disease progression and the efficacy of therapy in resource-poor countries …

Effect of ex vivo storage and Cyto-Chex on the expression of P-selectin glycoprotein ligand-1 (PSGL-1) on human peripheral leukocytes

A Schumacher - Journal of immunological methods, 2007 - Elsevier
P-selectin glycoprotein ligand-1 (PSGL-1) is expressed on leukocytes and its expression is
elevated in asthma and chronic obstructive pulmonary disease. This study assessed …

Evaluation of the Blood Stabilizers TransFix™ and Cyto-Chex® BCT for Low-Cost CD4 T-Cell Methodologies

MM Plate, R Louzao, PM Steele, V Greengrass… - Viral …, 2009 - liebertpub.com
Abstract TransFix™ and Cyto-Chex® BCT (blood collection tube) reagents have been
shown to maintain whole blood integrity for delayed immunophenotyping by flow cytometry …

自制全血质控品用于T 淋巴细胞质量控制分析

周崇兴, 梁淑家, 李剑军, 郝玲, 齐明山, 臧丹艳… - 中国公共卫生, 2018 - zgggws.com
自制全血质控品用于T 淋巴细胞质量控制分析 Page 1 • 检验技术 • 自制全血质控品用于T 淋巴细胞
质量控制分析* 周崇兴1,梁淑家1,李剑军1,郝玲2,齐明山2,臧丹艳1,沈智勇1 [摘 要]目的 评价 …