Theranostic radionuclides: recent advances in production methodologies

SM Qaim - Journal of radioanalytical and nuclear chemistry, 2019 - Springer
Various concepts involved in the quantification of radiation dose while following the
theranostic approach in nuclear medicine are outlined. The availability of the relevant …

Radionuclide candidates for β+ γ coincidence PET: an overview

M Sitarz, JP Cussonneau, T Matulewicz… - Applied Radiation and …, 2020 - Elsevier
Following the advancement of the Positron Emission Tomography (PET), a novel technique
emerged which takes advantage of the gamma quanta emitted, in some cases, after the β+ …

[HTML][HTML] Cyclotron production of 68Ga via the 68Zn (p, n) 68Ga reaction in aqueous solution

MK Pandey, JF Byrne, H Jiang… - American journal of …, 2014 - ncbi.nlm.nih.gov
The objective of the present work is to extend the applicability of the solution target approach
to the production of 68 Ga using a low energy cyclotron. Since the developed method does …

Production of copper-64 and gallium-68 with a medical cyclotron using liquid targets

F Alves, VHP Alves, SJC Do Carmo… - … Physics Letters A, 2017 - World Scientific
This work describes the production of two clinically relevant metal radioisotopes 6 4 Cu and
6 8 Ga with a medical cyclotron by the irradiation of liquid targets. New results are presented …

[HTML][HTML] Recommended nuclear data for medical radioisotope production: diagnostic positron emitters

FT Tárkányi, AV Ignatyuk, A Hermanne… - … of Radioanalytical and …, 2019 - Springer
An IAEA coordinated research project that began in 2012 and ended in 2016 was primarily
dedicated to the compilation, evaluation and recommendation of cross-section data for the …

Production of Ga-68 with a General Electric PETtrace cyclotron by liquid target

S Riga, G Cicoria, D Pancaldi, F Zagni, S Vichi… - Physica medica, 2018 - Elsevier
Purpose In recent years the use of 68 Ga (t 1/2= 67.84 min, β+: 88.88%) for the labelling of
different PET radiopharmaceuticals has significantly increased. This work aims to evaluate …

Cyclotron production of 68Ga in a liquid target: effects of solution composition and irradiation parameters

MK Pandey, JF Byrne, KN Schlasner, NR Schmit… - Nuclear Medicine and …, 2019 - Elsevier
Abstract Objectives To optimize 68 Ga production using a liquid cyclotron target,
investigations were performed to compare production yields using different concentrations of …

Very high specific activity 66/68Ga from zinc targets for PET

JW Engle, V Lopez-Rodriguez… - Applied Radiation and …, 2012 - Elsevier
This work describes the production of very high specific activity 66/68Ga from natZn (p, n)
and 66Zn (p, n) using proton irradiations between 7 and 16MeV, with emphasis on 66Ga for …

[HTML][HTML] Cyclotron production of PET radiometals in liquid targets: Aspects and prospects

MK Pandey, TR DeGrado - Current radiopharmaceuticals, 2021 - ncbi.nlm.nih.gov
The present review describes the methodological aspects and prospects of the production of
Positron Emission Tomography (PET) radiometals in a liquid target using low-medium …

[HTML][HTML] Automated radiosynthesis of 68Ga for large-scale routine production using 68Zn pressed target

AH Alnahwi, S Tremblay, S Ait-Mohand… - Applied Radiation and …, 2020 - Elsevier
Abstract Gallium-68 (68 Ga) has attracted increasing interest in recent years due to the
expanding clinical applications of 68 Ga-based radiopharmaceuticals (Rahbar et al., 2017) …