Characterization of XR‐RV3 GafChromic® films in standard laboratory and in clinical conditions and means to evaluate uncertainties and reduce errors

J Farah, A Trianni, O Ciraj‐Bjelac, I Clairand… - Medical …, 2015 - Wiley Online Library
Purpose: To investigate the optimal use of XR‐RV3 GafChromic® films to assess patient
skin dose in interventional radiology while addressing the means to reduce uncertainties in …

Review of backscatter measurement in kilovoltage radiotherapy using novel detectors and reduction from lack of underlying scattering material

DJ Eaton, PJ Doolan - Journal of applied clinical medical …, 2013 - Wiley Online Library
Lack of underlying material can lead to dose reduction in kilovoltage radiotherapy
treatments because of backscatter reduction. Conversely, the use of lead shielding can lead …

Australasian recommendations for quality assurance in kilovoltage radiation therapy from the Kilovoltage Dosimetry Working Group of the Australasian College of …

R Hill, B Healy, D Butler, D Odgers, S Gill, J Lye… - Australasian Physical & …, 2018 - Springer
Abstract The Australasian College of Physical Scientists and Engineers in Medicine
(ACPSEM) Radiation Oncology Specialty Group (ROSG) formed a series of working groups …

Evaluation and clinical implementation of in vivo dosimetry for kV radiotherapy using radiochromic film and micro-silica bead thermoluminescent detectors

AL Palmer, SM Jafari, I Mone, S Muscat - Physica Medica, 2017 - Elsevier
Purpose kV radiotherapy treatment calculations are based on flat, homogenous, full-scatter
reference conditions. However, clinical treatments often include surface irregularities and …

Relative dosimetry measurements in kilovoltage X-rays with OSLDs

A McGrath - Physical and Engineering Sciences in Medicine, 2020 - Springer
Dosimetry for kilovoltage X-ray units requires a careful choice of equipment due a typically
high energy dependence of standard detectors. The use of optically stimulated …

Investigation of backscatter factor in medical radiography using anthropomorphic phantom by optically stimulated luminescence dosimeter

A Arimoto, Y Asada - Biomedical Physics & Engineering Express, 2021 - iopscience.iop.org
At the diagnostic reference level (DRL) related to medical radiation, DRL quantity for general
radiography is the entrance surface dose (ESD). Calculation of the ESD in medical …