Magnetic resonance electrical impedance tomography (MREIT) for high-resolution conductivity imaging

EJ Woo, JK Seo - Physiological measurement, 2008 - iopscience.iop.org
Cross-sectional imaging of an electrical conductivity distribution inside the human body has
been an active research goal in impedance imaging. By injecting current into an electrically …

Magnetic resonance electrical impedance tomography (MREIT)

JK Seo, EJ Woo - SIAM review, 2011 - SIAM
Magnetic resonance electrical impedance tomography (MREIT) is a recently developed
medical imaging modality visualizing conductivity images of an electrically conducting …

[图书][B] Nonlinear inverse problems in imaging

JK Seo, EJ Woo - 2012 - books.google.com
This book provides researchers and engineers in the imaging field with the skills they need
to effectively deal with nonlinear inverse problems associated with different imaging …

Electrical Properties Tomography Based on Maps in MRI: Principles, Applications, and Challenges

J Liu, Y Wang, U Katscher, B He - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
Objective: The purpose is to provide a comprehensive review of the electrical properties
tomography (EPT) technique, which was introduced to image the electrical properties (EPs) …

In Vivo High-ResolutionConductivity Imaging of the Human Leg Using MREIT: The First Human Experiment

HJ Kim, YT Kim, AS Minhas, WC Jeong… - IEEE transactions on …, 2009 - ieeexplore.ieee.org
We present the first in vivo cross-sectional conductivity image of the human leg with 1.7 mm
pixel size using the magnetic resonance electrical impedance tomography (MREIT) …

[图书][B] Electro-magnetic tissue properties MRI

JK Seo, EJ Woo, U Katscher, Y Wang - 2014 - books.google.com
This is the first book that presents a comprehensive introduction to and overview of electro-
magnetic tissue property imaging techniques using MRI, focusing on Magnetic Resonance …

[图书][B] Biomedical signals, imaging, and informatics

JD Bronzino, DR Peterson - 2015 - api.taylorfrancis.com
During the past eight years since the publication of the third edition—a three-volume set—of
The Biomedical Engineering Handbook, the eld of biomedical engineering has continued to …

Experimental performance evaluation of multi‐echo ICNE pulse sequence in magnetic resonance electrical impedance tomography

AS Minhas, WC Jeong, YT Kim, Y Han… - Magnetic …, 2011 - Wiley Online Library
Latest experimental results in magnetic resonance electrical impedance tomography
(MREIT) demonstrated high‐resolution in vivo conductivity imaging of animal and human …

MREIT conductivity imaging of the postmortem canine abdomen using CoReHA

K Jeon, AS Minhas, YT Kim, WC Jeong… - Physiological …, 2009 - iopscience.iop.org
Magnetic resonance electrical impedance tomography (MREIT) is a new bio-imaging
modality providing cross-sectional conductivity images from measurements of internal …

CoReHA: conductivity reconstructor using harmonic algorithms for magnetic resonance electrical impedance tomography (MREIT)

KW Jeon, CO Lee, HJ Kim, EJ Woo… - Journal of Biomedical …, 2009 - koreascience.kr
Magnetic resonance electrical impedance tomography (MREIT) is a new medical imaging
modality providing cross-sectional images of a conductivity distribution inside an electrically …