A comprehensive review of loosening detection methods for threaded fasteners

J Huang, J Liu, H Gong, X Deng - Mechanical Systems and Signal …, 2022 - Elsevier
Loosening of threaded fasteners can cause preload decline, induce bolt fatigue fracture, and
severely compromise the reliability of mechanical products. Loosening detection is an …

A review of bolt tightening force measurement and loosening detection

R Miao, R Shen, S Zhang, S Xue - Sensors, 2020 - mdpi.com
Pre-stressed bolted joints are widely used in civil structures and industries. The tightening
force of a bolt is crucial to the reliability of the joint connection. Loosening or over-tightening …

Multi-scale contact induced period-doubling vibrations in rotor systems: Numerical and experimental studies

R Zhao, Y Xu, Z Zhao, Z Li, Z Chen, Z Chen… - Mechanical Systems and …, 2023 - Elsevier
Bolted disk structure has the advantages of easy production and assembly and it is widely
adopted in the design of gas turbine rotors. However, the discontinuity of bolted structure …

Vibration-based diagnostics of radial clearances and bolts loosening in the bearing supports of the heavy-duty gearboxes

P Krot, V Korennoi, R Zimroz - Sensors, 2020 - mdpi.com
The problem solved in this research is the diagnosis of the radial clearances in bearing
supports and the loosening of fastening bolts due to their plastic elongation (creep) or weak …

Coupling effects with vibration-based estimation of individual bolt tension in multi-bolt structures

M Brøns, A Plaugmann, A Fidlin, JJ Thomsen - Journal of Sound and …, 2022 - Elsevier
Recent work with various single-bolt experimental setups has shown promising results for
applying a vibration-based bolt tension estimation procedure. To estimate tension, the novel …

[HTML][HTML] The mechanical behaviour of a slip joint for an offshore wind turbine: First monitoring and modelling results

M Mojto, A Cabboi - Thin-Walled Structures, 2024 - Elsevier
This study aims at shedding light on the mechanical behaviour of a prototype monopile–
wind turbine tower connection, constituted by a slip joint. Selected examples of data set …

Transmissibility Function-based diagnosis of a class of bolted Beam-like structures with nonlinear Fault-induced loads and nonlinear boundary conditions

Q Li, Z Li, M Liao, F Yang, X Jing - Mechanical Systems and Signal …, 2023 - Elsevier
Bolted beam-like engineering structures are frequently encountered with dynamic load-
caused bolt faults like fatigue crack and loosening during operation. Bolt faults can seriously …

Estimating bolt tension from vibrations: Transient features, nonlinearity, and signal processing

M Brøns, JJ Thomsen, SM Sah, D Tcherniak… - Mechanical Systems and …, 2021 - Elsevier
Monitoring and control of tension in bolted joints is a difficult task that has received long-time
attention. A newly proposed technique is to hammer-impact the bolts and estimate the …

Multi-bolt looseness positioning using multivariate recurrence analytic active sensing method and MHAMCNN model

Y Chen, L Zhu, Z Gao, W Li… - Structural Health …, 2024 - journals.sagepub.com
The piezoelectric active sensing method has been proven to be an effective, nondestructive
approach for bolt looseness monitoring. The conventional damage index relies on the …

Electromechanical impedance instrumented wearable piezoelectric ring-type sensor for bolted connection monitoring

J Wu, Y Chen, J Wang, Z Liu, W Li - IEEE Sensors Journal, 2023 - ieeexplore.ieee.org
Due to the loss of preload, structural failure caused by bolt loosening is common in
engineering structures. Effective monitoring of bolted connections is of great importance in …