Corrosion inhibition of aluminium by rare earth chlorides

AK Mishra, R Balasubramaniam - Materials Chemistry and Physics, 2007 - Elsevier
The corrosion inhibition of pure Al due to addition of different concentrations of LaCl3 and
CeCl3 in 3.5% NaCl solution has been investigated. Polarization resistance studies …

Optical imaging and three dimensional reconstruction of the concentration field around a crystal growing from an aqueous solution: A review

A Srivastava, K Muralidhar, PK Panigrahi - Progress in crystal growth and …, 2012 - Elsevier
Investigation of transport phenomena around a crystal growing from its aqueous solution
has been a subject of intensive research over the last few decades. It involves the …

[图书][B] Approximation theory and algorithms for data analysis

A Iske - 2018 - Springer
This textbook offers an elementary introduction to the theory and numerics of approximation
methods, combining classical topics of approximation with selected recent advances in …

Performance of iterative tomographic algorithms applied to non-destructive evaluation with limited data

PMV Subbarao, P Munshi, K Muralidhar - Ndt & E International, 1997 - Elsevier
Iterative tomographic algorithms have been applied to the reconstruction of a two-
dimensional object with internal defects from its projections. Nine distinct algorithms with …

Analysis of dynamic bias error in X-ray tomographic reconstructions of a three-phase flow system

S Shakya, P Munshi, M Behling, A Luke… - International journal of …, 2014 - Elsevier
Void fraction is one of the most important parameters to analyze various properties of multi-
phase flows. Bubbles can arrange themselves in different manners and their distribution …

Super resolution CT imaging using higher order total variation (HOTV) technique

S Sarkar, P Wahi, P Munshi - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
The present study focuses on the performance upgradation of a table-top computed
tomography (CT) scanning instrument. The size restriction of the detectors of table-top CT …

Corrosion inhibition of 6061‐SiC by rare earth chlorides

AK Mishra, R Balasubramaniam… - Anti-Corrosion Methods …, 2007 - emerald.com
Purpose–The research work in this paper aims to focus on understanding the corrosion
inhibition of 6061‐8 (vol.%) SiC in 3.5 per cent NaCl solution using different concentrations …

Relative estimation of scattering noise and electronic noise of a radiation detector

K Kumari, M Goswami - Measurement Science and Technology, 2023 - iopscience.iop.org
This study investigates two unavoidable noise factors: electronic noise (EN) and radiation
scattering, associated with detectors and their electronics. This study proposes a novel …

Error analysis of tomographic filters II: results

P Munshi, RKS Rathore, KS Ram, MS Kalra - NDT & E International, 1993 - Elsevier
The convolution backprojection algorithm (CBP) has been studied from the point-of-view of
the already published error formula which relates the error in reconstructions, under certain …

Development and application of color schlieren technique for investigation of three-dimensional concentration field

A Srivastava - Journal of crystal growth, 2013 - Elsevier
The present work describes the development and application of rainbow schlieren
deflectometry technique for the investigation of the three-dimensional concentration field …