Experimental study of tornado-like loading on rectangular prisms

Z Tang, D Zuo, D James, Y Eguchi, Y Hattori - Journal of Fluids and …, 2022 - Elsevier
To study the interaction between bluff bodies and tornado-like flow, two rectangular prisms
of different depth to height ratios were tested in a two-celled tornado-like vortex generated …

Smart urban windcatcher: Conception of an AI-empowered wind-channeling system for real-time enhancement of urban wind environment

B Zhang, CY Li, H Kikumoto, J Niu, KT Tim - Building and Environment, 2024 - Elsevier
The dense configuration and rapid proliferation of high-rise buildings in central Hong Kong
have led to increasing stagnation of pedestrian-level airflows, lowering the wind speed and …

[HTML][HTML] Research on the impact of irregular structure group construction on rail transit bridge piers and its response to wind load

Y Wang, Z Chen, Y Qi - Scientific reports, 2023 - nature.com
The possibility of deformation and collision in existing railway bridge foundation structures
due to the construction of a group of large irregular structures in close proximity and their …

Wind load effect of single-column-supported two-plate billboard structures

Z Li, D Wang, X Chen, S Liang, J Li - Journal of Wind Engineering and …, 2018 - Elsevier
Wind tunnel studies are conducted to investigate the wind load effect of a representative
single-column-supported two-plate billboard structure. Firstly, synchronous pressure …

[PDF][PDF] Wind load characteristics of large billboard structures with two-plate and three-plate configurations

D Wang, X Chen, J Li, H Cheng - Wind Struct, 2016 - researchgate.net
This paper presents a wind tunnel study of wind loads of the large billboard structures with
two-plate and three-plate configurations. Synchronous dynamic pressures on the surfaces of …

[HTML][HTML] Wind Vulnerability of Flexible Outdoor Single-Post Billboards

R Salgado-Estrada, A Galván, JY Moreno-Martínez… - Applied Sciences, 2023 - mdpi.com
Increased temperature due to global climate change is increasing the magnitude and
frequency of extreme winds making billboard structures more vulnerable. This paper …

Characteristics of wind induced net force and torque on a rectangular sign measured in the field

DA Smith, D Zuo, KC Mehta - Journal of Wind Engineering and Industrial …, 2014 - Elsevier
Full-scale field tests for a billboard sign are conducted at the Wind Science and Engineering
(WISE) field site to provide a benchmark for model scale tests performed in the wind tunnel …

Field investigation and structural analysis of wind-induced collapse of outdoor single-post billboards

J Wen, Q Xie - Engineering Failure Analysis, 2020 - Elsevier
Outdoor single-post billboards, which consist of a supporting steel column and two or three
billboard panels, are widely used in public places. However, wind-induced collapse of these …

[HTML][HTML] CFD simulation study on wind load of perforated traffic sign board

J Xu, H Xu, C Zeng, C Xie, J Guo - PLoS one, 2020 - journals.plos.org
Traffic sign boards are often blown away by strong winds, seriously endangering the safety
of vehicles and pedestrians. To increase their resistance to strong winds, sign boards are …

[PDF][PDF] Investigation of wind-induced dynamic and aeroelastic effects on variable message signs

D Meyer, AG Chowdhury, P Irwin - Wind Struct, 2015 - researchgate.net
Tests were conducted at the Florida International University (FIU) Wall of Wind (WOW) to
investigate the susceptibility of Variable Message Signs (VMS) to wind induced vibrations …