Polypropylene‐based soft ternary blends for power cable insulation at low‐to‐high temperature

SK Hong, SH Lee, JA Han, MS Ahn… - Journal of Applied …, 2022 - Wiley Online Library
Although cross‐linked polyethylene (XLPE) has been widely used as a power cable
insulation material in electricity infrastructure for decades, it is necessary to find alternatives …

A search coil design method of PMSM for detection of inter-turn short-circuit fault

R Li, H Fang, D Li, R Qu, S Yang… - IEEE Transactions on …, 2023 - ieeexplore.ieee.org
Fault diagnosis systems based on search coils are widely used for detecting the interturn
short-circuit fault, which is one of the most common electrical faults in electrical machines …

Residual life assessment of 110 kV XLPE cable

Z Zhang, PDS Assala, L Wu - Electric Power Systems Research, 2018 - Elsevier
In electric power transmission, 110 kV XLPE cables have been given a wide usage recently.
Specific samples are selected as specimens of accelerated thermal aging tests and are …

Morphological, structural, and dielectric properties of thermally aged AC 500 kV XLPE submarine cable insulation material and its deterioration condition assessment

Z Liu, J Hao, R Liao, J Li, Z Gao, Z Liang - IEEE Access, 2019 - ieeexplore.ieee.org
Cross-linked polyethylene (XLPE) has been widely used as insulation material for cables. In
2019, the highest voltage level AC 500 kV XLPE submarine cable has been operated in …

Influence of oxygen diffusion on thermal ageing of cross-linked polyethylene cable insulation

Y Zhang, Z Hou, K Wu, S Wang, J Li, S Li - Materials, 2020 - mdpi.com
Thermal ageing of cross-linked polyethylene (XLPE) cable insulation is an important issue
threatening the safe operation of power cables. In this paper, thermal ageing of XLPE was …

Space charge behavior in XLPE cable insulation under ac stress and its relation to thermo-electrical aging

D He, X Wang, H Liu, Q Li… - IEEE Transactions on …, 2018 - ieeexplore.ieee.org
The space charge features of cable insulation peelings are investigated under ac stress as a
function of electrical aging imposed previously on cable sections. The investigated samples …

Effect of electrical and thermal stressing on charge traps in XLPE cable insulation

A Tzimas, SM Rowland… - IEEE Transactions on …, 2012 - ieeexplore.ieee.org
Insulation peelings were taken from a single 90 kV ac transmission cable whose segments
had been stressed for between~ 8000 and 10 000 h either at elevated temperature (363 K) …

Harmonic-based thermal analysis of electric arc furnace's power cables considering even current harmonics, forced convection, operational scheduling, and …

A Jamali-Abnavi, H Hashemi-Dezaki, A Ahmadi… - International Journal of …, 2021 - Elsevier
The thermal analysis of power cables to improve their lifetime and reliability is essential.
Also, the current harmonics intensify the excessive heat condition of power cables. Although …

[PDF][PDF] 退役高压交联聚乙烯电缆绝缘老化状态分析

罗潘, 任志刚, 徐阳, 冯义, 叶宽, 李华春… - 电工技术 …, 2013 - dgjsxb.ces-transaction.com
摘要通过对北京多根退役110kV 及220kV 交联聚乙烯电缆绝缘层进行差式扫描量热和力学性能
分析, 研究了电缆绝缘材料聚集态结构及宏观力学性能变化. DSC 研究表明: 运行10 …

Effects of interfacial pressure on tracking failure between XLPE and silicon rubber

BX Du, L Gu - IEEE Transactions on Dielectrics and Electrical …, 2010 - ieeexplore.ieee.org
XLPE power cables are increasingly used in power distribution system for their excellent
mechanical and electrical performance. However, interface between XLPE and silicon …